| Electronic Components Datasheet Search |
|
TMUX1511PWR Datasheet(PDF) 13 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMUX1511PWR Datasheet(HTML) 13 Page - Texas Instruments |
|
13 / 22 page ![]() 13 TMUX1511 www.ti.com SCDS390 – SEPTEMBER 2018 Product Folder Links: TMUX1511 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated Feature Description (continued) 8.3.4 Powered-off Protection Powered-off protection up to 3.6 V on the signal path of the TMUX1511 provides isolation when the supply voltage is removed (VDD = 0 V). When the TMUX1511 is powered-off the I/Os of the device remain in a high-Z state. Powered-off protection minimizes system complexity by removing the need for power supply sequencing on the signal path. The device performance remains within the leakage performance mentioned in the Electrical Specifications. For more information on 1.8 V logic implementations refer to Eliminate Power Sequencing with Powered-off Protection Signal Switches 8.3.5 Fail-Safe Logic The TMUX1511 support Fail-Safe Logic on the control input pins (SELx) allowing for operation up to 5.5 V, regardless of the state of the supply pin. This feature allows voltages on the digital control pins to be applied before the supply pin, protecting the device from potential damage. Fail-Safe Logic minimizes system complexity by removing the need for power supply sequencing on the logic control pins. For example, the Fail-Safe Logic feature allows the select pins of the TMUX1511 to be ramped to 5.5 V while VDD = 0 V. Additionally, the feature enables operation of the TMUX1511 with VDD = 1.5 V while allowing the select pins to interface with a logic level of another device up to 5.5 V. 8.4 Device Functional Modes The select (SELx) pins are active-high logic pins that control the connection between the source (Sx) and drain (Dx) pins of the device. The TMUX1511 has internal weak pull-down resistors (6 MΩ) to GND so that it powers- on with the switches disabled. When a given select pin of the TMUX1511 is pulled high, the corresponding switch conducts from the source to drain. When any of the select pins are pulled low, the corresponding switch is in an open state (HI-Z). Each channel of the TMUX1511 can be controlled independently through the associated select pin, or all four select pins can be tied together for simultaneous control of all channels with a single GPIO. 8.5 Truth Tables Table 1 shows the truth table for the TMUX1511. Table 1. TMUX1511 Truth Table SELx Sx / Dx: STATE 0 Hi-Z (OFF) 1 Conducting (ON) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |