| Electronic Components Datasheet Search |
|
TP2111 Datasheet(PDF) 12 Page - 3PEAK INC. |
|
|
|||||||||||||||||||||||||||||
TP2111 Datasheet(HTML) 12 Page - 3PEAK INC. |
|
12 / 18 page ![]() 12 TP2111/TP2111N/TP2112/TP2114 Nanopower 300nA, 1.8V, Rail-to-Rail Input/Output Op-amps REV1.0 www.3peakic.com Buffered Chemical Sensor (pH) Probe The TP211x OPA has input bias current in the fA range. This is ideal in buffering high impedance chemical sensors such as pH probe. As an example, the circuit in Figure 5 eliminates expansive low-leakage cables that that is required to connect pH probe to metering ICs such as ADC, AFE and/or MCU. A TP211x OPA and a lithium battery are housed in the probe assembly. A conventional low- cost coaxial cable can be used to carry OPA’s output signal to subsequent ICs for pH reading. R1 10M Ω R2 10M Ω COAX BATTERY 3V (DURACELL DL1620) ALL COMPONENTS CONTAJNED WITHIN THE pH PROBE GENERAL PURPOSE COMBINATION pH PROBE (CORNING 476540) pH PROBE To ADC/AFE/MCU TP211x Figure 5: Buffer pH Probe Portable Gas Sensor Amplifier Gas sensors are used in many different industrial and medical applications. Gas sensors generate a current that is proportional to the percentage of a particular gas concentration sensed in an air sample. This output current flows through a load resistor and the resultant voltage drop is amplified. Depending on the sensed gas and sensitivity of the sensor, the output current can be in the range of tens of microamperes to a few milli-amperes. Gas sensor datasheets often specify a recommended load resistor value or a range of load resistors from which to choose. There are two main applications for oxygen sensors – applications which sense oxygen when it is abundantly present (that is, in air or near an oxygen tank) and those which detect traces of oxygen in parts-per-million concentration. In medical applications, oxygen sensors are used when air quality or oxygen delivered to a patient needs to be monitored. In fresh air, the concentration of oxygen is 20.9% and air samples containing less than 18% oxygen are considered dangerous. In industrial applications, oxygen sensors are used to detect the absence of oxygen; for example, vacuum-packaging of food products. The circuit in Figure 6 illustrates a typical implementation used to amplify the output of an oxygen detector. With the components shown in the figure, the circuit consumes less than 300nA of supply current ensuring that small form-factor single- or button-cell batteries (exhibiting low mAh charge ratings) could last beyond the operating life of the oxygen sensor. The precision specifications of these amplifiers, such as their low offset voltage, low VOS TC, low input bias current, high CMRR, and high PSRR are other factors which make these amplifiers excellent choices for this application. 100k Ω 1% 100 Ω 1% VOUT 100k Ω 1% 10M Ω 1% 2 O I 2 1 in Air ( 21% O ) 0.7 OUT DD VV I uA Oxygen Sensor City Technology 4OX2 TP211x Figure 6 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |