| Electronic Components Datasheet Search |
|
TC-72AD-PT-R2-F-S-AH Datasheet(PDF) 2 Page - FOTEK CONTROLS CO., LTD. |
|
|
|||||||||||||||||||||||||||||
TC-72AD-PT-R2-F-S-AH Datasheet(HTML) 2 Page - FOTEK CONTROLS CO., LTD. |
|
2 / 5 page ![]() 10 Sensor Type Output Method Control Method Proportion Band Cycle Time Manual Reset Unit of Degree Setting Method Setting Range Output Method Setting Method Setting Range Output Method Power Supply Current Consumption Insulation Resistance Dielectrical Strength Operating Temp./Hum Vibration Resistance Panel Thickness K < CA > , J < IC > or PT-100 Relay< 5A / 250VAC >,Voltage < 20mA / 12V >,Linear < 4~20mA > P+D ON/OFF , ON/OFF or Proportion Appro 2.5% of F.S. 2 Sec or 20 Sec < ON+OFF > Trimmer , Range 10 C or F Trimmer ( AL ) 0 ~ +50 , 0 ~ -50 or -50 ~ +50 of Setting Value Relay , 0.5A/250VAC Trimmer (HB) 0.5A~25A ; 1.0A~50A Relay , 0.5A/250VAC 110 / 220 VAC 20% 50 / 60Hz 2.5VA max. Over 50M /500 VDC Between Power And Another Terminal 1.0~8.0mm Over 2.5KV / 1min Between Power And Another Terminal -20 C ~+60 C ; 35%~85% RH 10~55Hz / 1.5mm , 2Hrs in X.Y.Z Direction Attachment CT provided with Heater Break Alarm type only. CT General Data AL Alarm Al HB Alarm Hb Electrical Data Mechanical Data 9 6 6 7 8 9 10 7 8 9 10 5 5 4 4 3 3 1 1 With Cold Junction Compensation, Suited to Operated at -20 C ~ +60 C All type with Sensor Break Alarm LED. With P+D Control to Control Temperature Easily. High Accuracy of Displaying & Setting Less than 0.5% of F.S. With Stand-by/Over-heat Alarm.( Optioned ). With Heater Break Alarm.( Optioned ). -20 C ~ +60 C P+D 0.5% ( ) ( ) Guiding of Model Product Range of Setting TC = Temperature Controller Digital Switch Trimmer Outline 0 = -99 ~ + 99 05 = -50 ~ +50 48 = 48(W) X 48(H) mm X mm 1 = 0 ~ +199 1 = 0 ~ +100 4896 = 48(W) X 96(H) mm X mm 3 = 0 ~ +399 2 = 0 ~ +200 72 = 72(W) X 72(H) mm X mm 5 = 0 ~ +599 4 = 0 ~ +400 96 = 96(W) X 96(H) mm X mm 9 = 0 ~ +999 6 = 0 ~ +600 Method of Setting 11 = 0 ~ +1199 12 = 0 ~ +1200 D = Digital Swith Unit of Degree A = Trimmer F = F Method of Display non = C A = Analog Deviation Meter Method of Control D = Digital LED Display S = ON/OFF N = Without Display non = P+D ON/OFF Type of Sensor Alarm PT = RTD PT-100 A = With Stand-by / Over Heat Alarm J = J Type Thermocouple AH = With Stand-by / Over Heat Alarm Non = K Type Thermocouple & Heater Break Alarm Method of Output Non = Without Alarm R = Relay (5A/250VAC) V = Voltage (20mA/12V) L = Linear (4~20mA) Ex. TC - 4896 D A - PT - R 3 - F - S - A 2 2 5.8 21.0 30.0 40.0 3.5 2 7.5 25.0 3.0 10.0 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |