2 / 6 page ![]() Installing the WLB92 Industrial LED Light Bar (AC Quick Disconnect Models) Figure 1. Attaching the snap brackets (step 6) Figure 2. Installing the cascade cover (step 9) 1. Attach the snap brackets to the light. 2. Select a suitable horizontal or vertical dry mounting location. The maximum distance to the power receptacle cannot be farther than the length of the power cord used. 3. Place the light in the mounting location and mark the positions of the snap bracket mounting holes. 4. Remove the brackets from the light. 5. Drill the holes and use appropriate screws to secure the snap bracket to the mounting location. 6. Snap the light onto the brackets. 7. When installing cascading lights, repeat steps 1 through 6 to mount additional lights. See the application note in the Specifications section for the maximum cascaded lights and maximum allowed cable run when choosing mounting locations. 8. Connect the cascaded lights together using an applicable cordset (see Accessories (p. 5)). 9. Install the supplied cover over the output connector on the last light in the chain. 10. Plug the power cord from the first light into the wall outlet. A 3 m (10 ft) cord is available for applications requiring a longer cord for cabinet installations. CAUTION: To reduce the risk of fire, electrical shock, or injury to personal: • Use only insulated staples or plastic ties to secure cords • Route and secure cords so that they will not be pinched or damaged when the cabinet is pushed to the wall • Position the portable cabinet light with respect to the cabinet so the lamp replacement markings are able to be read during relamping • Do not recess into ceilings or soffits • Do not conceal the cords. The National Electrical Code (NEC) does not permit cords to be concealed where damage to insulation may go unnoticed. To prevent fire danger, do not run cords behind walls, ceilings, soffits, or cabinets where it may be inaccessible for examination. Cords should be visually examined periodically and immediately replaced when any damage is noted. CAUTION: To Reduce the Risk of Fire. Do not install the 550 mm models in a compartment smaller than 305 mm by 305 mm by 675 mm. Do not install the 1100 mm models in a compartment smaller than 305 mm by 305 mm by 1350 mm. WLB92 Industrial LED Light Bar (AC Quick Disconnect) 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 183984 Rev. H |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |