| Electronic Components Datasheet Search |
|
CSAS3F3RY2202 Datasheet(PDF) 95 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
CSAS3F3RY2202 Datasheet(HTML) 95 Page - Eaton All Rights Reserved. |
|
95 / 102 page ![]() V8-T3-94 Volume 8—Sensing Solutions CA08100010E—September 2017 www.eaton.com 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3.16 Inductive Proximity Sensors E51 Modular Limit Switch Style Sensors Technical Data and Specifications E51 Modular Limit Switch Style Sensors Wiring Diagrams Pin numbers are for reference, rely on pin location when wiring. E51 Modular Limit Switch Style Sensors Note 1 Changing output switch on sensor head will reverse output function (NO becomes NC, and NC becomes NO). Description Specification Output rating (NEMA D150) AC/DC models 0.5 A continuous AC models 1 A continuous DC models 0.6 A continuous Protection Latching short-circuit protection on two-wire AC/DC models; DC models: resettable short-circuit protection Switching rate AC models: 15 Hz; DC models: 50 Hz Indicator LEDs Lights when output is ON. One LED for each output Alternate frequency Standard and alternate frequencies allow side-by-side operation without interference Enclosure material Zinc die cast Gasket material Viton Enclosure ratings NEMA 3, 3S, 4, 4X, 6, 6P, 12 and 13 (IP67); E51SCN sensor body only: NEMA 4, 4X and 13 Hazardous locations ratings Class I Division II—GRPS ABCD Class II Division II—GRPS F and G Class III Division 2 Temperature range –13 to 158 °F (–25 to 70 °C) Torque requirements Switch body screws: 25–30 in-lbs; sensing head screws: 14–18 in-lbs Vibration 10–55 Hz, 1 mm amplitude Shock 30 g, 11 ms, 1/2 sine wave Humidity 95% non-condensing Burden current <25 mA OFF-state leakage DC version: 120 μA; two-wire AC: 1.9 mA maximum; three-wire AC: 1.1 mA ON-state leakage <2.5 Vdc Power-up delay <150 ms Operating Voltage Output Terminal and Cable Models Mini-Connector Models (Face View Male Shown) Two-Wire Sensors 20–264 Vac or Vdc 50/60 Hz NO or NC (NO shown, can be changed to NC using switch on sensor head) Four-Wire Sensors 120 Vac 50/60 Hz NO and NC 1 10–30 Vdc NO and NC NPN 1 NO and NC PNP 1 2 1 4 3 L2 or (–) L1 or +V Load Black White Green L1 or (–) L2 or +V Load 2 1 4 3 L2 L1 Load Load Black White Orange Red Green Load Load N.C. N.O. L2 L1 2 1 4 3 (–) +V Load Load Black White Orange Red Green (–) +V Load Load N.O. N.C. 2 1 4 3 (–) +V Load Load Black White Orange Red Green (–) +V Load Load N.C. N.O. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |