| Electronic Components Datasheet Search |
|
SN74LVC2T45YZP Datasheet(PDF) 16 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
SN74LVC2T45YZP Datasheet(HTML) 16 Page - Texas Instruments |
|
16 / 32 page ![]() VCC1 VCC1 VCC2 SYSTEM-1 SYSTEM-2 1 2 3 4 8 7 6 5 DIR CTRL I/O-1 Pullup/Down or Bus Hold(1) VCC2 I/O-2 Pullup/Down or Bus Hold(1) 16 SN74LVC2T45 SCES516K – DECEMBER 2003 – REVISED JUNE 2017 www.ti.com Product Folder Links: SN74LVC2T45 Submit Documentation Feedback Copyright © 2003–2017, Texas Instruments Incorporated (1) SYSTEM-1 and SYSTEM-2 must use the same conditions, that is, both pullup or both pulldown. 9.2.2 Bidirectional Logic Level-Shifting Application Figure 20 shows the SN74LVC2T45 being used in a bidirectional logic level-shifting application. Because the SN74LVC2T45 does not have an output-enable (OE) pin, the system designer should take precautions to avoid bus contention between SYSTEM-1 and SYSTEM-2 when changing directions. Figure 20. Bidirectional Logic Level-Shifting Application 9.2.2.1 Design Requirements Please refer to Unidirectional Logic Level-Shifting Application. 9.2.2.2 Detailed Design Procedure Table 4 shows data transmission from SYSTEM-1 to SYSTEM-2 and then from SYSTEM-2 to SYSTEM-1. Table 4. Data Transmission Sequence STATE DIR CTRL I/O-1 I/O-2 DESCRIPTION 1 H Out In SYSTEM-1 data to SYSTEM-2 2 H Hi-Z Hi-Z SYSTEM-2 is getting ready to send data to SYSTEM-1. I/O-1 and I/O-2 are disabled. The bus- line state depends on pullup or pulldown.(1) 3 L Hi-Z Hi-Z DIR bit is flipped. I/O-1 and I/O-2 still are disabled. The bus-line state depends on pullup or pulldown.(1) 4 L In Out SYSTEM-2 data to SYSTEM-1 9.2.2.2.1 Enable Times Calculate the enable times for the SN74LVC2T45 using the following formulas: • tPZH (DIR to A) = tPLZ (DIR to B) + tPLH (B to A) • tPZL (DIR to A) = tPHZ (DIR to B) + tPHL (B to A) • tPZH (DIR to B) = tPLZ (DIR to A) + tPLH (A to B) • tPZL (DIR to B) = tPHZ (DIR to A) + tPHL (A to B) In a bidirectional application, these enable times provide the maximum delay from the time the DIR bit is switched until an output is expected. For example, if the SN74LVC2T45 initially is transmitting from A to B, then the DIR bit is switched; the B port of the device must be disabled before presenting it with an input. After the B port has been disabled, an input signal applied to it appears on the corresponding A port after the specified propagation delay. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |