5 / 8 page ![]() IN74ACT161 5 TIMING REQUIREMENTS (VCC=5.0V±10%, CL=50pF,Input tr=tf=3.0 ns) Guaranteed Limit Symbol Parameter +25 ° C -40 ° C to +85 ° C Unit tSU Minimum Setup Time, Preset Data Inputs to Clock (Figure 4) 9.5 11.5 ns th Minimum Hold Time, Clock to Preset Data Inputs (Figure 4) 0 0 ns tSU Minimum Setup Time,Load to Clock (Figure 4) 8.5 9.5 ns th Minimum Hold Time, Clock to Load (Figure 4) -0.5 -0.5 ns tSU Minimum Setup Time, Enable T or Enable P to Clock (Figure 5) 5.5 6.5 ns th Minimum Hold Time, Clock to Enable T or Enable P (Figure 5) 0 0 ns tw Minimum Pulse Width, Clock (Load) (Figure 1) 3.0 3.5 ns tw Minimum Pulse Width, Clock (Count)(Figure 1) 3.0 3.5 ns tw Minimum Pulse Width, Reset (Figure 2) 3.0 7.5 ns trec Minimum Recovery Time, Reset to Clock (Figure 2) 0 0.5 ns |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|