2 / 4 page ![]() 3M Fire Protection Products 3M™ Fire Barrier Block B258 3M™ Fire Barrier Plank PK39 3M™ Fire Barrier Plug PLG2 and PLG4 Page 2 of 4 Performance and Typical Physical Properties Note: The following technical information and data should be considered representative or typical only and should not be used for specification purposes. Test Method Surface Burning: Flame Spread 5, Smoke Development 250 ASTM E 84 Air Leakage: Less than 1 CFM/sq. ft. @ 400°F less than 1 CFM/sq. ft. @ ambient. UL 1479 Section 6 Product Size Color Mass Units/Ctn. Wt./Ctn 3M Fire Barrier Block B258 2-3/8 in. x 5-1/8 in. x 7-7/8 in. (60 mm x 130 mm x 200 mm) Maroon 575g 12 15.2 lbs. 6,9kg 3M Fire Barrier Plank PK39 2-3/8 in. x 5-1/8 in. x 39-3/8 in. (60 mm x 130 mm x 1000 mm) Maroon 2875g 3 19.0 lbs. 8,6kg 3M Fire Barrier Plug PLG2 2 in. diam. x 3-1/8 in. high Maroon 120g 4 1.1 lbs. 0,48kg 3M Fire Barrier Plug PLG4 4 in. diam. x 3-1/8 in. high Maroon 360g 4 3.2 lbs. 1,4kg Installation Techniques Consult a 3M Authorized Fire Protection Products Distributor/Dealer or Sales Representative for applicable UL, cUL, ULC, Interek or other third-party drawings and system details. Blocks and Planks 1. Install Fire Barrier Blocks or Fire Barrier Planks with the 5 in. (130mm) dimension projecting through the floor or wall and centered within the opening; minimum 4-1/2 in. seal thickness is required. 2. Continue to install Blocks/Planks until through opening is completely full, and blocks/planks are firmly packed together. Block/Plank can be re-sized in the field as needed provided the 5 in. (130mm) dimension is maintained through the opening. No compression is necessary. 3. Install Fire Barrier Rated Foam FIP 1-Step between the Blocks/Planks and the periphery of the opening and between Blocks/Planks and penetrants. Foam to be installed full depth of the Blocks/Planks. 4. Check for any openings between Blocks/Planks, framing, and penetrating items. Fill any visible openings with the required depth of Foam. Consult individual UL systems for Foam depth and location requirements. 5. To remove the Blocks/Planks, gently pull them out and place on a clean surface. After penetrants are routed through, or removed from the opening, replace the Blocks/Planks, making sure that they are firmly packed and fully filling the opening. Install Foam in any voids as required. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |