Specifications are subject to change without notice (21.03.08)
3
FMB01
Function Id - Double interval
Reset and Gate inputs working mode
If Reset contact is closed the relay is released and timing is
reset. Nothing else happens until Reset is released.
If Gate contact is closed the timing operation is freezed.
When it is released, if timing was in progress, it goes on
from the point reached at the moment of closing the Gate.
Function Rb - Symmetrical Recycler OFF first
Reset and Gate inputs working mode
If Reset contact is closed the function is interrupted, the
relay is released and timing is reset. Nothing else happens
until Reset is released.
If Gate contact is closed while recycling, the timing opera-
tion is freezed and the output is kept at the state it was
when Gate has been closed. When it is released, timing
goes on from the point reached at the moment of closing
the Gate.
Operating Diagrams
T
Powersupply
LED“POWER”
Triggerinput
T
T
T
T
RelaysON
T
Powersupply
LED“POWER”
Triggerinput
T
T
T
RelaysON
T
Powersupply
LED“POWER”
Triggerinput
T
T
T
T
RelaysON
Range and operation mode selection
Function Op - Delay ON Operate
Reset and Gate inputs working mode
If Reset contact is closed the relay is released and timing is
reset. Nothing else happens until Reset is released.
If Gate contact is closed the timing operation is freezed.
When it is released, if timing was in progress, it goes on
from the point reached at the moment of closing the Gate.
Powersupply
T
LED“POWER”
Triggerinput
RelaysON
T
Operating mode display window
Operating mode selector
(function Op, Rb, R, Id, Dr, In, Io)
Scale range display windows
Time unit selector (0.1s, sec, 10sec, min, etc.)
Time setting knob (set time)
Power indicator (green)
Time range selector 12 and 30 at full scale
Output indicator (yellow)
(Flashes when timer operates;
on when timer stops operating)
Time unit display window
Function R - Symmetrical Recycler ON first
Reset and Gate inputs working mode
If Reset contact is closed the function interrupted, the relay
is released and timing is reset. Nothing else happens until
Reset is released.
If Gate contact is closed while recycling, the timing opera-
tion is freezed and the output is kept at the state it was
when Gate has been closed. When it is released, timing
goes on from the point reached at the moment of closing
the Gate.



Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com