| Electronic Components Datasheet Search |
|
MRP6 Datasheet(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
MRP6 Datasheet(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 5 page ![]() MODEL: MRP6 MRP6 SPECIFICATIONS ES-4850 Rev.13 Page 1/5 http://www.m-system.co.jp/ Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features • Small-size control valve actuator • 1/1000 high resolution • Easy adjustment: electronic limiter at the valve open & closed positions • Overload protection • Various power inputs Typical Applications • Actuator for automatic control valve in pilotplants • Air-conditioning in buildings or plants • Micro-flow control for pharmaceutical injection • For small-size control valves MODEL: MRP6–[1][2][3][4]–[5][6][7] ORDERING INFORMATION • Code number: MRP6-[1][2][3][4]-[5][6][7] Specify a code from below for each of [1] through [7]. (e.g. MRP6-16LT-A0R) • Special input range (for codes Z and 0) [1] SPAN 1: 45 to 90 degrees 2: 90 to 180 degrees [2] OPERATION TIME, TORQUE 3: 4 seconds / 90°, 10 N·m 4: 7 seconds / 90°, 16 N·m 6: 13 seconds / 90°, 33 N·m [3] SEQUENTIAL CONTROL SIGNALS L: Full-open/-closed signal F: Forced open/close signal B: Full-open/-closed and forced open/close signals (Select 'With Terminal Box.') 0: Without [4] TERMINAL BOX T: With 0: Without [5] INPUT Current A: 4 – 20 mA DC (Input resistance 250 Ω) Z: Specify current (See INPUT SPECIFICATIONS) Voltage 6: 1 – 5 V DC (Input resistance approx. 1 MΩ) 0: Specify voltage (See INPUT SPECIFICATIONS) [6] CE MARKING C: With 0: Without [7] POWER INPUT AC Power K3: 100 – 120 V AC (Operational voltage range 90 – 132 V, 47 – 66 Hz) (Not selectable for CE) L3: 200 – 240 V AC (Operational voltage range 180 – 264 V, 47 – 66 Hz) (Not selectable for CE) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) GENERAL SPECIFICATIONS Degree of protection: IP66 Action: Direct or reverse; field selectable with DIP switches (factory set to “reverse”) (In “reverse” action, the output stem seen from the cover turns counterclockwise with an input signal increase.) Operation at abnormally low input: Counterclockwise turn, clockwise turn or stop; field selectable with DIP switches (factory set to“clockwise”) Note: Counterclockwise or clockwise if seen from the cover. Detectable input drop level: -16 ±2.5 % Electrical connection •Without terminal box Wiring conduit: G 1/2 female; cable connector with 1 meter wire (0.5 mm2) provided •Terminal box Wiring conduit: G 1/2 female (two) Terminal screws: M3 pillar terminal (Sequential control signal suffix code B) |
Similar Part No. - MRP6 |
|
Similar Description - MRP6 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |