| Electronic Components Datasheet Search |
|
700HTP-2 Datasheet(PDF) 1 Page - Fluke Corporation |
|
|
|||||||||||||||||||||||||||||
700HTP-2 Datasheet(HTML) 1 Page - Fluke Corporation |
|
1 / 2 page ![]() PN 4096896 September 2011 2011 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. How to Prime the Test Pump Before you connect the Pump to the Unit Under Test (UUT), the Pump must be filled with fluid and primed for use. Follow the directions below to prepare the Pump for use. 1. Fill the Pump with fluid: a. Remove the Reservoir Filler Cap (item .) b. Fill the Hydraulic Fluid Reservoir approximately two-thirds full (66 cc) with distilled water, mineral oil, or hydraulic oil. Note If water is used in the Pump, use only DISTILLED water and drain the water out of the Pump after use. c. Install the Reservoir Filler Cap (item .) Tighten by hand. 2. Prime the Pump: a. Adjust the Vernier Fine Adjustment Knob (item ) to the approximate middle-range. b. Turn the Pressure Bleed Knob (item ) clockwise until it stops in the full closed position. c. Squeeze the handles together to pump fluid. Pump fluid until fluid shows at the Pump Port. d. Attach the fluid hose to the Pump. e. Squeeze the handles together until fluid shows at the end of the hose. f. Attach the fluid hose to the Unit Under Test (UUT) and squeeze the Pump handles until pressure increases. g. Bleed the trapped air from the Pump. Pressurize the Pump to 1,000 psi then slowly turn the Pressure Bleed Knob (item ) counter-clockwise to release pressure. Notes • As the pressure rises it will be hard to squeeze the handles together. Use the Handle Limiter (item ) to limit the travel of the handles which will make them easier to squeeze together. To toggle the Handle Limiter on or off, squeeze the handles together and push the Handle Limiter (item ) in or out. • The rate at which the pressure increases is directly related to the test configuration (hose length and volume of UUT.) Replacement Parts Rebuild Kit, Fluke PN 4097836 Hydraulic Fluid Reservoir Rebuild Kit, Fluke PN 2844341 Handle Assembly Rebuild Kit, Fluke PN 2844352 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99 Fluke-700HTP-2 Hydraulic Test Pump Instruction Sheet Introduction The Fluke 700HTP-2 Hydraulic Test Pump (the Pump or Product) is a portable source of high pressure. Safety W Warning To prevent personal injury, use the Product only as specified, or the protection supplied by the Product can be compromised. Pump Specifications • Maximum pressure: 10,000 psi (690 bar) • Hydraulic media: distilled water, mineral based hydraulic oil, or up to hydraulic oil 100 (30 W). • Wetted materials: 303 stainless steel, aluminum, polyurethane, PTFE, nitrile, and nylon. • Weight: 1.29 lb (0.58 kg) • Dimensions: length 9.5 in (241 mm), width 6.1 in (155 mm), depth 2.6 in (66 mm) Box Contents • Model 700HTP-2 Hydraulic Test Pump with a 1/4-inch NPT tee installed. • Two 1/4-inch NPT male to 1/4-inch BSP female adapters. • One 1/4-inch NPT male to 1/4-inch NPT male fitting. • One 1/4-inch NPT male to 1/8-inch NPT male fitting. • Instruction Sheet How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 • Japan: +81-3-6714-3114 • Singapore: +65-738-5655 • Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. |
Similar Part No. - 700HTP-2 |
|
Similar Description - 700HTP-2 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |