| Electronic Components Datasheet Search |
|
0916607 Datasheet(PDF) 4 Page - PHOENIX CONTACT |
|
|
|||||||||||||||||||||||||||||
0916607 Datasheet(HTML) 4 Page - PHOENIX CONTACT |
|
4 / 5 page ![]() UT 6-TMC M... 103943_en_04 PHOENIX CONTACT 4 3.2 Effect on thermal tripping of mounting in rows The mutual thermal effect is tantamount to an increase in the ambient temperature (see page 5). This depends on the following: – The nominal current – The ambient temperature – The number of devices – The distance between devices The nominal device current can be either overdimensioned or limited. When the UT 6-TMC M is mounted in rows, the correction factor is usually in the range of 1.25 or at 80% (reciprocal) in relation to the limiting nominal current. These values apply in the event of continuous load and at an ambient temperature of +23°C. Since the thermal effect varies for each planned installation when mounting in rows, the correction factors must be defined individually and tested. Calculation example for overdimensioning 5 circuit breakers with I n = 10 A are to be mounted in rows. The ambient temperature is +23°C. 3.3 Internal resistance of the UT 6-TMC M Measurement between the LINE and LOAD connections. Tolerance: ±10% 4 Mechanical data NOTE: When mounted in rows with simultaneous load, a mutual thermal effect occurs. Nominal current when not mounted in rows I n = 10 A Typical correction factor d f = 1.25 Theoretical nominal current when mounting in rows I n row = 10 A X 1.25 = 12.5 A Nominal current Resistance 0.5 A 4.37 Ω 1.0 A 0.95 Ω 2.0 A 0.33 Ω 4.0 A 88.0 m Ω 5.0 A 55.8 m Ω 6.0 A 41.7 m Ω 8.0 A 22.2 m Ω 10.0 A 12.3 m Ω 12.0 A 10.9 m Ω 15.0 A 8.3 m Ω 16.0 A 7.7 m Ω Fixing Mounting method On a DIN rail according to DIN EN 60715, NS 35N/7,5 or NS 35/15 The tripping characteristics are not dependent on the mounting position. Plug-in bridge, for cross connection in the bridge shaft FBS x-6 plug-in bridge (see "Accessories" on page 2) Connection polarity Independent polarity (for DC) for the LINE and LOAD connections Suitability "Factory wiring" Weight 51 g Housing material PA 66 Fuse type Medium blow fuse Inflammability class according to UL 94 V0 Maximum number of cycles 6000 at 1 x I n Connection terminal block Screw connection M4 Connection capacity Solid Stranded With ferrule 1 conductor 0.2 mm² ... 10 mm² 0.2 mm² ... 10 mm² 0.25 mm² ... 6 mm² 2 conductors (two conductors with same cross-section, ferrule without plastic sleeve) 0.2 mm² ... 2.5 mm² 0.25 mm² ... 1.5 mm² 2 stranded conductors with a TWIN ferrule 0.5 mm² ... 4 mm² Stripping length 12 mm Tightening torque (EN 60934) 1.5 Nm ... 1.8 Nm |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |