| Electronic Components Datasheet Search |
|
NTS359 Datasheet(PDF) 1 Page - Astec America, Inc |
|
|
|||||||||||||||||||||||||||||
NTS359 Datasheet(HTML) 1 Page - Astec America, Inc |
|
1 / 2 page ![]() rev 12.19.05 Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 1 Special Features Electrical Specs 350 Watts NTS350 Series Input Input range 85-264 VAC; 120-300 VDC Frequency 47-440 Hz Inrush current 38 A max., cold start @ 25°C Efficiency 85% typical at full load EMI filter FCC Class B conducted and radiated CISPR 22 Class B conducted and radiated EN55022 Class B conducted and radiated VDE 0878 PT3 Class B conducted and radiated. Power factor 0.99 typical Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 VAC input Output Maximum power 200W convection; 350 W with 30 CFM forced air Adjustment range ±5% Standby output 5 V @ 2A regulated, ±5% Fan output 12 V @ 1A, -5 %, +7%, 0.5A for -CF version Hold-up time 20 ms @ 350 W load, 115 VAC nominal line at factory voltage setting Overload protection Short circuit protection on all outputs. Case overload protected @ 115-130% above peak rating Overvoltage protection 20% to 35% above nominal output Logic Control Power failure TTL logic signal goes high 100-500 msec after main output. It goes low at least 4 msec before loss of regulation Remote on/off Requires an external contact closure to inhibit outputs DC OK TTL logic goes high after the output is in regulation. It goes low when there is loss of regulation. Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. • Active power factor correction • IEC EN6100-3-2 compliance • Remote sense • Power fail and remote inhibit • Single wire current sharing • Built-in EMI filter • Low output ripple • 5V standby • 12V fan output • Overvoltage protection •Overload protection • Thermal overload protection • DC power good • Built in OR-ing diode / FET • Optional fan cover (-CF suffix) Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C Electromagnetic susceptibility: Designed to meet EN61000-4, -2, -4, -5, -11 Level 3 Humidity: Operating; non-condensing 10% to 90% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 2 G peak 8 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >1M hours at full load and 25°C ambient conditions TUV 60950 UL 60950 CSA 60950 NEMKO 60950 AUSTEL 60950 CB Certificate and report CE Mark (LVD) Environmental Total Power: 200-350 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Safety |
Similar Part No. - NTS359 |
|
Similar Description - NTS359 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |