| Electronic Components Datasheet Search |
|
HT46R53 Datasheet(PDF) 9 Page - Holtek Semiconductor Inc |
|
|
|||||||||||||||||||||||||||||
HT46R53 Datasheet(HTML) 9 Page - Holtek Semiconductor Inc |
|
9 / 42 page ![]() HT46R53/HT46R54 Rev. 1.40 9 July 12, 2005 28H to 7FH, is used for data and control information un- der instruction commands. All of the data memory areas can handle arithmetic, logic, increment, decrement and rotate operations directly. Except for some dedicated bits, each bit in the data memory can be set and reset by ²SET [m].i² and ²CLR [m].i². They are also indirectly ac- cessible through memory pointer registers (MP0;01H or MP1;03H). Indirect Addressing Register Location 00H and 02H are indirect addressing registers that are not physically implemented. Any read/write op- eration of [00H] ([02H]) will access the data memory pointed to by MP0 (MP1). Reading location 00H (02H) itself indirectly will return the result ²00H². Writing indi- rectly results in no operation. The memory pointer regis- ters (MP0 and MP1) are 7-bit registers. Accumulator - ACC The accumulator closely relates to ALU operations. It is also mapped to location ²05H² of the data memory which can operate with immediate data. The data move- ment between two data memories has to pass through the accumulator. Arithmetic and Logic Unit - ALU This circuit performs 8-bit arithmetic and logic operations. The ALU provides the following functions: · Arithmetic operations (ADD, ADC, SUB, SBC, DAA) · Logic operations (AND, OR, XOR, CPL) · Rotation (RL, RR, RLC, RRC) · Increment and Decrement (INC, DEC) · Branch decision (SZ, SNZ, SIZ, SDZ ....) The ALU not only saves the results of a data operation but also changes the status register. Status Register - STATUS This 8-bit register (0AH) contains the zero flag (Z), carry flag (C), auxiliary carry flag (AC), overflow flag (OV), power down flag (PDF), and watchdog time-out flag (TO). It also records the status information and controls the operation sequence. With the exception of the TO and PDF flags, bits in the status register can be altered by instructions like most other registers. Any data written into the status register will not change the TO and PDF flags. Addition opera- tions related to the status register may give different re- sults from those intended. The TO flag can be affected only by system power-up, a WDT time-out or executing the ²HALT² or ²CLR WDT² instruction. The PDF flag can be affected only by executing the ²HALT² or ²CLR WDT² instruction or a system power-up. The Z, OV, AC, and C flags reflect the status of the latest operations. On entering the interrupt sequence or exe- cuting the subroutine call, the status register will not be automatically pushed onto the stack. If the contents of the status is important, and if the subroutine is likely to corrupt the status register, the programmer should take precautions and save it properly. Interrupts The device provides an external interrupt, an internal timer/event counter interrupt, and an A/D converter in- terrupt. The interrupt control register (INTC;0BH) con- tains the interrupt control bits to set the enable/disable and the interrupt request flags. Once an interrupt subroutine is serviced, all the other in- terrupts will be blocked (by clearing the EMI bit). This scheme may prevent any further interrupt nesting. Other interrupt requests may occur during this interval but only the interrupt request flag is recorded. If a certain inter- Bit No. Label Function 0 C C is set if an operation results in a carry during an addition operation or if a borrow does not take place during a subtraction operation; otherwise C is cleared. C is also affected by a rotate through carry instruction. 1 AC AC is set if an operation results in a carry out of the low nibbles in addition or no borrow from the high nibble into the low nibble in subtraction; otherwise AC is cleared. 2 Z Z is set if the result of an arithmetic or logic operation is zero; otherwise Z is cleared. 3 OV OV is set if an operation results in a carry into the highest-order bit but not a carry out of the highest-order bit, or vice versa; otherwise OV is cleared. 4 PDF PDF is cleared by system power-up or executing the ²CLR WDT² instruction. PDF is set by executing the ²HALT² instruction. 5 TO TO is cleared by system power-up or executing the ²CLR WDT² or ²HALT² instruction. TO is set by a WDT time-out. 6, 7 ¾ Unused bit, read as ²0² Status (0AH) Register |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |