| Electronic Components Datasheet Search |
|
DOM40K3R032 Datasheet(PDF) 16 Page - Hanbit Electronics Co.,Ltd |
|
|
|||||||||||||||||||||||||||||
DOM40K3R032 Datasheet(HTML) 16 Page - Hanbit Electronics Co.,Ltd |
|
16 / 30 page ![]() HANBit HFDOM40K3R URL:www.hbe.co.kr 16 / 30 HANBit Electronics Co., Ltd. Rev. 2.0 (October. 2004) Cyl High(5) X Cyl Low(4) X Sec Num(3) X Sec Cnt(2) X Feature(1) X Identify Drive The Identify Drive command enables the host to receive parameter information from the CompactFlash Storage Card. This command has the same protocol as the Read Sector(s) command. The parameter words in the buffer have the arrangement and meanings defined in Table . All reserved bits or words are zero. Table 40 is the definition for each field in the Identify Drive Information. Table: Identify Drive Information Word Address Default Value Total Bytes Data Field Type Information 0 848Ah 2 General configuration – signature for the CompactFlash Storage Card 1 xxxxh 2 Default number of cylinders 2 0000h 2 Reserved 3 00xxh 2 Default number of heads 4 xxxxh 2 Number of unformatted bytes per track 5 xxxxh 2 Number of unformatted bytes per sector 6 xxxxh 2 Default number of sectors per track 7-8 xxxxh 4 Number of sectors per card (Word 7 = MSW , word 8 = LSW) 9 xxxxh 2 Vendor Unique 10-19 aaaa 20 Serial number in ASCII (Right Justified ) 20 xxxxh 2 Buffer type 21 xxxxh 2 Buffer size in 512 byte increments 22 0004h 2 # of ECC bytes passed on Read/Write Long Commands 23-26 aaaa 8 Firmware revision in ASCII. Big Endian Byte Order in Word 27-46 aaaa 40 Model number in ASCII (Left Justified) Big Endian Byte Order in Word 47 xxxxh 2 Maximum number of sectors on Read/Write Mutliple command 48 0000h 2 Double Word not supported 49 xx00h 2 Capabilities 50 0000h 2 Reserved 51 0x00h 2 PIO data transfer cycle timing mode 52 0000h 2 DMA data transfer cycle timing mode 53 0001h 2 Translation parameters are valid 54 Xxxxh 2 Current numbers of cylinders 55 xxxxh 2 Current numbers of heads 56 xxxxh 2 Current sectors per track 57-58 xxxxh 4 Current capacity in sectors(LBAs)(Word 57 = LSW , Word 58 = MSW) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |