| Electronic Components Datasheet Search |
|
PMC21 Datasheet(PDF) 22 Page - Endress+Hauser Group Services AG |
|
|
|||||||||||||||||||||||||||||
PMC21 Datasheet(HTML) 22 Page - Endress+Hauser Group Services AG |
|
22 / 48 page ![]() Cerabar PMC11, PMC21, PMP11, PMP21 22 Endress+Hauser Performance characteristics of metal process isolating diaphragm Reference operating conditions • As per IEC 60770 • Ambient temperature TA = constant, in the range: +21 to +33 °C (+70 to +91 °F) • Humidity φ = constant, in the range: 5 to 80 % rH • Ambient pressure pA = constant, in the range: 860 to 1060 mbar (12.47 to 15.37 psi) • Position of measuring cell = constant, in the range: horizontal ±1° (see also "Influence of the installation position" section → 23) • Zero based span • Process isolating diaphragm material: AISI 316L (1.4435) • Filling oil: synthetic oil polyalphaolefin FDA 21 CFR 178.3620, NSF H1 • Supply voltage: 24 V DC ±3 V DC • Load: 320 Ω (at 4 to 20 mA output) Measuring uncertainty for small absolute pressure measuring ranges The smallest extended uncertainty of measurement that can be delivered by our standards is: • in the range 1 to 30 mbar (0.0145 to 0.435 psi): 0.4 % of reading • in the range < 1 mbar (0.0145 psi): 1 % of reading. Influence of the installation position → 23 Resolution Current output: min. 1.6 μA Reference accuracy The reference accuracy contains the non-linearity [DIN EN 61298-2 3.11] including the pressure hysteresis [DIN EN 61298-23.13] and non-repeatability [DIN EN 61298-2 3.11] in accordance with the limit point method as per [DIN EN 60770]. Device % of the calibrated span to the maximum turn down Reference accuracy Non-linearity Non-repeatability PMP11 1) ±0.5 ±0.1 ±0.1 PMP21 ±0.3 ±0.1 ±0.1 1) For devices with 0 to 10 V output, a non-linearity of up to max. 0.3 V can occur for signal values below 0.015 V. Overview of the turn down ranges → 15 Thermal change of the zero output and the output span Measuring cell –20 to +85 °C (–4 to +185 °F) –40 to –20 °C (–40 to –4 °F) +85 to +100 °C (+185 to +212 °F) % of the calibrated span for TD 1:1 <1 bar (15 psi) <1 <1.2 ≥1 bar (15 psi) <0.8 <1 Long-term stability Device 1 year 5 years 8 years % of URL PMP11 PMP21 ±0.2 ±0.4 ±0.45 Switch-on time ≤2 s |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |