GX11LAB Datasheet(PDF) 4 Page - Sensata Technologies, Inc.

Part # GX11LAB
Description  150 Amp 12-800 Vdc Contactor
PDF  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  SENSATA [Sensata Technologies, Inc.]
Direct Link  https://www.sensata.com/
Logo SENSATA - Sensata Technologies, Inc.

GX11LAB Datasheet(HTML) 4 Page - Sensata Technologies, Inc.

  GX11LAB Datasheet HTML 1Page - Sensata Technologies, Inc. GX11LAB Datasheet HTML 2Page - Sensata Technologies, Inc. GX11LAB Datasheet HTML 3Page - Sensata Technologies, Inc. GX11LAB Datasheet HTML 4Page - Sensata Technologies, Inc.  
Zoom Inzoom in Zoom Outzoom out
 4 / 4 page
background image
Notes & Definitions:
1 Auxillary contact rating is 2A, 24Vdc Resistive load, 100,000
cycles. Minimum current is 0.1mA, 5V. The auxiliary contact is
mechanically linked to the main power contacts.
2 Contact resisitance measured at currents higher than 100A.
3 Operation time is measured at 25°C and includes maximum
7ms bounce.
4 Insulation resistance is 50 Mohms after life.
5 Contactor can operate up to 125°C in special cases - contact
GIGAVAC for details.
6 Contactor has two coils. Both are used for pick-up, and
then in approximately 75 milliseconds, one coil is electronically
removed from the coil drive circuit. The remaining coil supplies
low continuous hold power sufficient for the contactor to meet
all of its specified performance specifications. This provides low
coil power without PWM electronics that can cause EMI emissions
and/or cross-talk on control power.
7 Contactor is operated by a coil that changes resistance
with temperature. Since Pick-up Current, Coil Current and Coil
Power are specified at Nominal Voltage, they will be lower than
indicated at temperatures above 25°C and higher than indicated
at temperatures below 25°C. Similarly, Pick-up and Drop-out
Voltages will be higher than indicated at temperatures above
25°C and lower than indicated at temperatures below 25°C.
8 For pick-up testing of contactors with dual coils, the voltage
can not be ramped up slowly, but must be applied instantly to at
least the maximum Pick-up Voltage. Otherwise, the contactor will
not pick-up.
9 Limit make current to 500A to avoid contact welding. For AC
power switching cycles, contact factory.
APPLICATION NOTES
• Contactors feature internal transorb for coil suppression. No external
diodes should be added across the coil. The use of additional external coil
suppression can slow the release time and invalidate the life cycle ratings,
or can cause the contactor not to be able to interrupt the maximum current
specified. If lower coil back EMF is required, please contact GIGAVAC for
assistance.
• Power switching lifecycles are based on current flow from A2(+) to A1(-).
For best breaking performance, the contactor should be installed so that
current flows from A2(+) to A1(-). There are cases where the contactor will
interrupt power in the opposite direction but please contact GIGAVAC to
confirm suitability. Direction of current flow is not relevant during make
or when flowing on closed contacts. For bi-directional contactors, please
contact GIGAVAC.
• Applications with capacitors will require a pre-charge circuit.
• Electrical life rating is based on resistive load with 27µH maximum
inductance in circuit. Because your application may be different, we
suggest you test the contactor in your circuit to verify life is as required.
• End of life is defined as when the dielectric, insulation resistance or
contact resistance fails the specifications listed.
PART NUMBER SYSTEM
GX11
B
A
B
Coil Voltage
B = 12 Vdc, Internal Coil
Suppression
C = 24 Vdc, Internal Coil
Suppression
F = 48 Vdc, Internal Coil
Suppression
H = 72 Vdc, Internal Coil
Suppression
J = 120 Vdc, Internal
Coil Suppression
K = 120 Vac, Internal
Coil Suppression
L = 240 Vac, Internal
Coil Suppression
S = 12 Vdc, Low Power,
Internal Coil Suppression
T = 24 Vdc, Low Power,
Internal Coil Suppression
Coil
Termination
A = Flying leads
38 cm (15 in)
B = Flying leads
61 cm (24 in)
C = Flying leads
122 cm (48 in)
Auxiliary
Contact
Blank = None
B = SPST,
Normally Open
C = SPST,
Normally Closed
GIG AVAC® - 6382 Rose Lane - Carpinteria, CA 93013 - ph +1- 805 - 684 - 8401 - fa x +1- 805 - 684 - 8402
info @gigavac.com - w w w.gigavac.com - © Copy right 2003 -2014 GIG AVAC, LLC.
GX11
150+ Amp 12-800 Vdc
EPIC® Hermetic Sealed DC Contactor



Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com