| Electronic Components Datasheet Search |
|
CD2RMC Datasheet(PDF) 1 Page - Greystone Energy Systems Inc. |
|
|
|||||||||||||||||||||||||||||
CD2RMC Datasheet(HTML) 1 Page - Greystone Energy Systems Inc. |
|
1 / 2 page ![]() GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM ROOM CARBON DIOXIDE DETECTOR CD2RMC SERIES PRODUCT DESCRIPTION The room CO 2 transmitter device uses a highly accurate and reliable nondispersive infrared (NDIR) sensor in an attractive, low profile enclosure for room applications to monitor CO 2 levels. The sensor uses dual wavelength optics and LTA (long term adjustment) signal processing technology to deliver industry leading long-term accuracy and reliability. These technology features ensure optimum measurement stability for both periodic and constant occupancy applications, so the device is equally suitable for a classroom or a hospital room. Standard features include a field selectable output signal of either 4-20 mA, 0-5 Vdc or 0-10 Vdc for the highest versatility, programmable CO 2 measurement span, a backlit alpha-numeric LCD and easy menu operation for configuration. Optional features include a resistive temperature sensor output (with LCD display of temperature in either °C or °F), 2 button setpoint adjustment, a control relay with programmable setpoint, hysteresis and time delay, and a dry-contact override switch. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The CD2RMC series can be mounted directly to a single gang electrical box or directly to a wall. The backplate includes many mounting hole configurations to allow for mounting on a variety of electrical boxes. The basic CD2RMC has a 3 wire configuration with a screw block terminal provided for connection to the Building Automation System. GAS TYPE DETECTED Carbon Dioxide (CO 2) SENSOR TYPE Dual channel non-dispersive infrared (NDIR) SENSOR ACCURACY ± (30ppm + 3% of measured value) MEASUREMENT RANGE 0-2000ppm, adjustable 1000 - 10000ppm TEMPERATURE DEPENDENCY ±2.5ppm/ °C RESPONSE TIME 20 seconds (T63) WARM-UP TIME 1 minute SENSOR COVERAGE AREA 100 m2 (1000ft2) typical SENSOR LIFE SPAN >15 years TRANMSITTER ACCURACY ±0.25% of span (including linearity, hysteresis and repeatability) POWER SUPPLY 24 Vdc ±20% or 24 Vac ±10% (non-isolated half-wave rectified) PROTECTION CIRCUITRY Reverse voltage protected and transient protected INPUT VOLTAGE EFFECT Negligible over specified operating range OUTPUT SIGNAL TYPE 4-20 mA (3-wire), 0-5 or 0-10 Vdc (field selectable) CURRENT CONSUMPTION Current: 75 mA @ 24 Vdc max, 150 mA @ 24 Vac max Voltage: 50 mA @ 24 Vdc max, 100 mA @ 24 Vac max OUTPUT DRIVE @ 24 VDC Current: 550Ω max Voltage: 10,000Ω min AMBIENT OPERATING RANGE 0 to 50°C (32 to 122°F), 0 to 95 %RH non-condensing STORAGE TEMPERATURE -40 to 70°C (-40 to 158°F) LCD DISPLAY Units: ppm (CO 2), °C/°F (optional temperature/setpoint) Range: 0 to 10000ppm, 0 to 50°C (32 to 122°F) Size: 35mm W x 15mm H (1.4” x 0.6”), 2 lin x 8 character, alpha-numeric Digit Height: 2-line x 8 character OPTIONAL TEMPERATURE SENSOR Type: Thermistor and RTD (see ordering chart) Accuracy: See ordering chart Output: 2-wire resistive OPTIONAL RELAY (2-WIRE OUTPUT) Rating: Form A (N.O.), 2 Amps @ 140 Vac / 30 Vdc OPTIONAL OVERRIDE SWITCH (2-WIRE OUTPUT) Rating: 50 mA @ 12 Vdc max OPTIONAL SETPOINT CONTROL Type: Front panel up/down pushbuttons Range: ±10 resistive steps, range 16 to 26°C in 0.5°C increments or 60 to 80°F in 1°F increments Midpoint: Default 21°C/70°F, programmable 18 to 25°C (64 to 77°F) Resolution: Programmable 0.5 / 1°C/°F Action: Programmable direct or reverse acting ENCLOSURE Material: ABS, White Dimensions: 84mm W x 119mm H x 29mm D (3.3” x 4.7” x 1.15”) Protection: IP30 (NEMA 1) WIRING Screw terminal block (14 to 22 AWG) APPROVALS CE COUNTRY OF ORIGIN Canada SPECIFICATIONS NOTE: This CO 2 sensor incorporates a Self Calibration feature to correct CO2 sensor drift. This feature is recommended for applications where the CO 2 level will be close to normal (400 ppm) at least one hour per day. If the monitored space is occupied 24 hours or consistently maintains higher or lower levels of CO 2, it is recommended that this feature be turned off, but yearly calibration will be required. 58 mm 2.3" 82.6 mm 3.25" 29 mm 1.15" 119 mm 4.7" 84 mm 3.3" |
Similar Part No. - CD2RMC |
|
Similar Description - CD2RMC |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |