Back Button DP83TC811SWRHARQ1 Datasheet HTML 60Page - Texas Instruments DP83TC811SWRHARQ1 Datasheet HTML 61Page - Texas Instruments DP83TC811SWRHARQ1 Datasheet HTML 62Page - Texas Instruments DP83TC811SWRHARQ1 Datasheet HTML 63Page - Texas Instruments DP83TC811SWRHARQ1 Datasheet HTML 64Page - Texas Instruments DP83TC811SWRHARQ1 Datasheet HTML 65Page - Texas Instruments DP83TC811SWRHARQ1 Datasheet HTML 66Page - Texas Instruments DP83TC811SWRHARQ1 Datasheet HTML 67Page - Texas Instruments DP83TC811SWRHARQ1 Datasheet HTML 68Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 64 / 140 page
background image
8.6.21 LSR Register 0x0133 – Link Status Results Register
Figure 8-35. Link Status Results Register (LSR)
15
14
13
12
11
10
9
8
Reserved
Link Status
Reserved
RO-0
RO-0
RO-0101 1110 0
7
6
5
4
3
2
1
0
Scrambler Lock Local Receiver
Status
Remote
Receiver Status
RO-0
RO-0
RO-0
Table 8-43. LSR Field Descriptions
BIT
FIELD
TYPE
DEFAULT
DESCRIPTION
15:13
Reserved
RO
0
Reserved
12
Link Status
RO
0
Unlatched Link Status:
1 = Valid Link Established
0 = No Link
11:3
Reserved
RO
0101 1110
0
Reserved
2
Scrambler Lock
RO
0
Scrambler Lock:
1 = Scrambler Locked
0 = Scrambler Not Locked
1
Local Receiver Status
RO
0
Local Receiver Status:
1 = Local PHY received link valid
0 = Local PHY received link invalid
0
Remote Receiver Status
RO
0
Remote Receiver Status:
1 = Remote PHY received link valid
0 = Remote PHY received link invalid
8.6.22 TDRR Register 0x016B – TDR Results Register
Figure 8-36. TDR Results Register (TCRR)
15
14
13
12
11
10
9
8
Reserved
Fault Status
Fault Type
RO-0
RO-0
RO-0
7
6
5
4
3
2
1
0
Fault Location
RO-0
Table 8-44. TDRR Field Descriptions
BIT
FIELD
TYPE
DEFAULT
DESCRIPTION
15:10
Reserved
RO
0
Reserved
9
Fault Status
RO
0
Fault Status:
1 = Fault Detected
0 = No Fault Detected
8
Fault Type
RO
0
Fault Type:
1 = SHORT Fault
0 = OPEN Fault
Note: Only valid when bit[9] = 1.
7:0
Fault Location
RO
0
Fault Location:
To calculate fault location in meters, convert binary field to
decimal form and multiply by 1.5.
Note: Only valid when bit[9] = 1.
DP83TC811-Q1
SNLS742 – SEPTEMBER 2023
www.ti.com
64
Submit Document Feedback
Copyright © 2023 Texas Instruments Incorporated
Product Folder Links: DP83TC811-Q1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com