2 / 2 page ![]() Dimensions AV 100-2000 (in mm. 1 mm = 0.0394 inch) Remarks • I S is positive when VP is applied on terminal +HT. • This is a standard model. For different versions, please contact us. Mechanical characteristics • General tolerance ± 1 mm • Transducer fastening 2 holes ∅ 6.5 mm Distance between holes 124mm • Fastening & connection of primary 2 x M5 • Fastening & connection of secondary 3 x M5 or 3 Faston 6.35 x 0.8mm Output connections must be made with screened cables Front view Top view Left view Secondary terminals Terminal + : Supply voltage +12 .. 24 V Terminal M : Measure Terminal - : Supply voltage - 12 .. 24V Connection • Recommended fastening torque 2.2 Nm or 1.62 Lb - Ft. + M - HT+ HT- AV 100-2000 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|