13 / 35 page ![]() 6.3.3 Wide Input Common-Mode Voltage Range The INA185 supports input common-mode voltages from –0.2 V to +26 V. Due to the internal topology, the common-mode range is not restricted by the power-supply voltage (VS) as long as VS stays within the operational range of 2.7 V to 5.5 V. The ability to operate with common-mode voltages greater or less than VS allows the INA185 to be used in high-side, as well as low-side, current-sensing applications, as shown in Figure 6-1. Bus Supply ±0.2 V to +26 V High-Side Sensing Low-Side Sensing LOAD Common-mode voltage (VCM) is bus-voltage dependent. Common-mode voltage (VCM) is always near ground and is isolated from bus-voltage spikes. Direction of Positive Current Flow IN+ Direction of Positive Current Flow RSENSE RSENSE IN± IN+ IN± Figure 6-1. High-Side and Low-Side Sensing Connections 6.3.4 Precise Low-Side Current Sensing When used in low-side current sensing applications, the offset voltage of the INA185 is within ±55 µV for A2, A3 and A4 devices. The low offset performance of the INA185 has two main benefits. First, the low offset allows these devices to be used in applications that must measure current over a wide dynamic range. In this case, the low offset improves the accuracy when the sensed currents are on the low end of the measurement range. The other advantage of low offset is the ability to sense lower voltage drop across the sense resistor accurately, thus allowing a lower-value shunt resistor. Lower-value shunt resistors reduce power loss in the current sense circuit, and help improve the power efficiency of the end application. The gain error of the INA185 is specified to be within 0.2% of the actual value for A1, A2, and A3 devices. As the sensed voltage becomes much larger than the offset voltage, this voltage becomes the dominant source of error in the current sense measurement. 6.3.5 Rail-to-Rail Output Swing The INA185 allows linear current sensing operation with the output close to the supply rail and GND. The maximum specified output swing to the positive rail is 25 mV, and the maximum specified output swing to GND is only 3.5 mV. To compare the output swing of the INA185 to an equivalent operational amplifier (op amp), the inputs are overdriven to approximate the open-loop condition specified in many operational amplifier data sheets. The current-sense amplifier is a closed-loop system, therefore the output swing to GND can be limited by the offset voltage and amplifier gain during unidirectional operation (VREF = 0 V) when there is zero current flowing through the sense resistor. To define the maximum output voltage under the zero current condition, the INA185 Electrical Characteristics table specifies a maximum output voltage of 6 mV for the A1 device, and 12 mV for all other devices. www.ti.com INA185 SBOS378A – MARCH 2019 – REVISED NOVEMBER 2023 Copyright © 2024 Texas Instruments Incorporated Submit Document Feedback 13 Product Folder Links: INA185 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |