1 / 2 page ![]() 060303/8 LEM www .lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. page 1/2 Current Transducer LAH 100-P For the electronic measurement of currents : DC, AC, pulsed ..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data I PN Primary nominal r.m.s. current 100 A I P Primary current, measuring range 1) 0 .. 160 A R M Measuring resistance @ T A = 70°C T A = 85°C R M min RM max R M min RM max with ± 12 V @ I PN [± A DC ] 0 63 0 57 Ω @ I PN [A RMS ] 2) 0 11 0 5 Ω with ± 15 V @ I PN [± A DC ] 20 120 45 114 Ω @ I PN [A RMS ] 2) 20 51 45 45 Ω @ I P < I PN 3) I SN Secondary nominal r.m.s. current 50 mA K N Conversion ratio 1 : 2000 V C Supply voltage (± 5 %) ± 12 .. 15 V I C Current consumption 10 (@ ± 15 V)+I S mA V d R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 5 kV V e R.m.s. voltage for partial discharge extinction @ 10 pC > 2 kV V w Impulse withstand voltage 1.2/50 µs > 12 kV Accuracy - Dynamic performance data X Accuracy 4) @ I PN, TA = 25°C ± 0.25 % ε L Linearity error < 0.15 % Typ Max I O Offset current @ T A = 25°C ± 0.15 mA I OM Residual current @ I P = 0, after an overload of 5 x IPN ± 0.10 ± 0.15 mA I OT Thermal drift of I O 0°C .. + 70°C ± 0.10 ± 0.40 mA - 25°C .. + 85°C ± 0.10 ± 0.50 mA t r a Reaction time @ 10 % of I PN < 200 ns t r Response time 5) @ 90 % of I PN < 500 ns di/dt di/dt accurately followed > 200 A/µs f Frequency bandwidth (- 1 dB) DC .. 200 kHz General data T A Ambient operating temperature - 25 .. + 85 °C T S Ambient storage temperature - 40 .. + 90 °C R S Secondary coil resistance @ T A = 70°C 115 Ω @ T A = 85°C 121 Ω Insulating material group I m Mass 24 g Standards EN 50178 : 1997 Notes : 1) For 10 s, with R M ≤ 25 Ω (VC = ± 15 V) - 2) 50 Hz Sinusoidal - 3) The measuring resistance R M min may be lower (see "LAH Technical Information" leaflet) - 4) Without I O & IOM - 5) With a di/dt of 100 A/µs. Features • Closed loop (compensated) current transducer using the Hall effect • Printed circuit board mounting • Insulated plastic case recognized according to UL 94-V0. Advantages • Excellent accuracy • Very good linearity • Low temperature drift • Optimized response time • Wide frequency bandwidth • No insertion losses • High immunity to external interference • Current overload capability. Applications • AC variable speed drives and servo motor drives • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) • Switched Mode Power Supplies (SMPS) • Power supplies for welding applications. I PN = 100 A 16052 |
Similar Part No. - LAH100-P |
|
Similar Description - LAH100-P |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |