| Electronic Components Datasheet Search |
|
EVAL-AD7764EBZ Datasheet(PDF) 21 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
EVAL-AD7764EBZ Datasheet(HTML) 21 Page - Analog Devices |
|
21 / 32 page ![]() AD7764 Rev. 0 | Page 21 of 32 AD7764 FUNCTIONALITY SYNCHRONIZATION The SYNC input to the AD7764 provides a synchronization function that allows the user to begin gathering samples of the analog front-end input from a known point in time. The SYNC function allows multiple AD7764s, operated from the same master clock, that use common SYNC and RESET signals to be synchronized so that each ADC simultaneously updates its output register. Connect common MCLK, SYNC and RESET signals to all AD7764 devices in the system. On the falling edge of the SYNC signal, the digital filter sequencer is reset to 0. The filter is held in a reset state until a rising edge of the SCO senses SYNC high. Thus, to perform a synchronization of devices, a SYNC pulse of a minimum of 2.5 ICLK cycles in length can be applied, synchronous to the falling edge of SCO. On the first rising edge of SCO after SYNC goes logic high, the filter is taken out of reset, and the multiple parts gather input samples synchronously. Following a SYNC, the digital filter needs time to settle before valid data can be read from the AD7764. The user knows there is valid data on the SDO line by checking the FILTER-SETTLE status bit (see D7 in Table 9) that is output with each conversion result. The time from the rising edge of SYNC until the FILTER- SETTLE bit asserts depends on the filter configuration used. See the Theory of Operation section and the values listed in Table 6 for details on calculating the time until FILTER-SETTLE asserts. Note that the FILTER_SETTLE bit is designed as a reactionary flag to indicate when the conversion data output is valid. OVERRANGE ALERTS The AD7764 offers an overrange function in both a pin and status bit output. The overrange alerts indicate when the voltage applied to the AD7764 modulator input pins exceeds the limit set in the overrange register, indicating that the voltage applied is approaching a level where the modulator will be overranged. To set this limit, the user must program the register. The default overrange limit is set to 80% of the VREF voltage (see the AD7764 Registers section). The OVERRANGE pin outputs logic high to alert the user that the modulator has sampled an input voltage greater in magnitude than the overrange limit as set in the overrange register. The OVERRANGE pin is set to logic high when the modulator samples an input above the overrange limit. Once the input returns below the limit, the OVERRANGE pin returns to zero. The OVERRANGE pin is updated after the first FIR filter stage. Its output changes at the ICLK/4 frequency. The OVR status bit is output as Bit D6 on SDO during a data conversion, and can be checked in the AD7764 status register. This bit is less dynamic than the OVERRANGE pin output. It is updated on each conversion result output, that is, the bit changes at the output data rate. If the modulator has sampled a voltage input that exceeded the overrange limit during the process of gathering samples for a particular conversion result output, then the OVR bit is set to logic high. LOGIC LEVEL HI LO LOGIC LEVEL HI LO OUTPUT FREQUENCY OF FIR FILTER 1 = ICLK/4 OVERRANGE LIMIT OVERRANGE LIMIT OBSOLUTE INPUT TO AD7764 [(VIN+) – (VIN–)] OUTPUT DATA RATE (ODR) (ICLK/DECIMATION RATE t t Figure 38. OVERRANGE Pin and OVR Bit vs. Absolute Voltage Applied to Modulator The output points from FIR Filter 1 in Figure 38 are not drawn to scale relative to the output data rate points. The FIR Filter 1 output is updated either 16×, 32×, or 64× faster than the output data rate depending on the decimation rate in operation. POWER MODES During power-up, the AD7764 defaults to operate in normal power mode. There is no register write required. The AD7764 also offers low power mode. To operate the device in low power mode, the user sets the LPWR bit in the control register to logic high (See Figure 39). Operating the AD7764 in low power mode has no impact on the output data rate or available bandwidth. SCO (O) CONTROL REGISTER ADDRESS 0x0001 LOW POWER MODE DATA 0x0010 FSI (I) SDI (I) 32 × tSCO Figure 39. Write Scheme for Low Power Mode The AD7764 features a RESET/PWRDWN pin. Holding the input to this pin logic low places the AD7764 in power-down mode. All internal circuitry is reset. To utilize the RESET functionality, pulse the input to this pin low for a minimum of one MCLK period. This action resets the internal circuitry. When the AD7764 receives a logic high input on the RESET/ PWRDWN pin, the device powers up. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |