16 / 81 page ![]() ABB 13 AC1615S - 03/10 Ts3 150A 600VAC ∆ / 225A, 480VAC Thermal-Magnetic General The Ts3 breaker family ranges from 15 through 225 amperes. The Ts3 trip mechanisms are non-interchangeable and use sensitive electromagnetic relays for overcurrent trip protection. Heat sensitive bimetals are used for thermal overcurrent protection. Short-circuit current protection begins at 10 times the thermal rating of the breaker and uses a magnetic coil principle. Standards The UL489/CSA C22.2 No. 5 version of Ts3 also carries an IEC-60947-2 rating. Versions To meet all application needs, the Ts3 is available in various versions: T = Thermal-magnetic D = Molded case switch M = Magnetic only (MCP) Performance Level Each version is also available in different maximum fault interrupting levels N = Normal H = High L = Extra high Number of Poles In UL/CSA form, the Ts3 is available in two pole or three pole versions, both with the same dimensions. A four-pole version is also available in the N version. For price estimation, add 35% to list price of selected version three pole breaker, contact ABB for details. Molded Case Switches UL/CSA switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. IEC type molded case switches with no trip protection are also available. Reverse Feeding All versions of the Ts3 family are suitable for reverse feed application. (1) 15-30A and 175-200-225A are 65kA at 480VAC (2) Ts3 175A, 200A, 225A are rated 480VAC / 500DVC maximum (3) Ts3 175A, 200A, 225A (4) 2 poles in series (5) 3 poles in series Ts3 Ts3 Dimensions 3P Fixed Version 6.7H x 4.13W x 4.07D Weight 6.75 (Ibs) UL/CSA Interrupting Capacity (kA RMS) UL489 / CSA C22.2 Voltage N H L 240 VAC 65 100 150 480 VAC 25 50 85 (1) 600 VAC (2) 14 14 25 500 VDC (4) 35 50 65 600 VDC (5) 20 35 50 Ts3/225A 500VDC (3) 20 35 50 IEC-60947-2 Interrupting Capacity (kA RMS) Voltage N H L 230 VAC 65 100 170 380/400/415VAC 35 65 85 440 VAC 30 50 65 500 VAC 25 40 50 690 VAC 14 18 20 500 VDC 35 50 65 750 VDC 20 35 50 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |