Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

ASC7531AM10 Datasheet(PDF) 7 Page - List of Unclassifed Manufacturers

Part # ASC7531AM10
Description  LOW-VOLTAGE 1-WIRE DIGITAL TEMPERATURE SENSOR AND VOLTAGE MONITOR
PDF  18 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  ETC2 [List of Unclassifed Manufacturers]
Direct Link  
Logo ETC2 - List of Unclassifed Manufacturers

ASC7531AM10 Datasheet(HTML) 7 Page - List of Unclassifed Manufacturers

Back Button ASC7531AM10 Datasheet HTML 3Page - List of Unclassifed Manufacturers ASC7531AM10 Datasheet HTML 4Page - List of Unclassifed Manufacturers ASC7531AM10 Datasheet HTML 5Page - List of Unclassifed Manufacturers ASC7531AM10 Datasheet HTML 6Page - List of Unclassifed Manufacturers ASC7531AM10 Datasheet HTML 7Page - List of Unclassifed Manufacturers ASC7531AM10 Datasheet HTML 8Page - List of Unclassifed Manufacturers ASC7531AM10 Datasheet HTML 9Page - List of Unclassifed Manufacturers ASC7531AM10 Datasheet HTML 10Page - List of Unclassifed Manufacturers ASC7531AM10 Datasheet HTML 11Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 18 page
background image
- 7 -
© Andigilog, Inc. 2006
www.andigilog.com
December 2006 - 70A05012
aSC7531A / aSC7531B
8
8
8
8
8
Target Address
Write Length
Read Length
GetDIB Cmd
FCS
0x48
0x01
0x08
0xF7
0x23
8
8
8
8
8
DIB Byte 1
…
DIB Byte 7
DIB Byte 8
FCS
(data)
(data)
(data)
(data)
(data dependent)
Figure 5. GetDIB() Command (8-byte read length)
Ping() Command
The Ping() command provides a safe means for software to verify that a device is responding at a particular address.
Write Data Length:
0x00
Read Data Length:
0x00
Command Code:
none
8
8
8
8
Target Address
Write Length
Read Length
FCS
0x48
0x00
0x00
0xD7
Figure 6. Example of Ping()
ResetDevice() Command
The ResetDevice() command is used to reset all device functions to their power-on reset values. It is used by the system to recover
from serious hardware or bus errors.
Write Data Length:
0x01
Read Data Length:
0x00
Command Code:
0xF6
8
8
8
8
8
Target Address
Write Length
Read Length
ResetDevice
Command
FCS
0x48
0x01
0x00
0xF6
0x8C
Figure 7. ResetDevice() format targeting a non-default address
8
8
8
8
Target Address
Write Length
Read Length
ResetDevice
Command
0x00
0x01
0x00
0xF6
Figure 8. ResetDevice() format targeting the default address



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com