| Electronic Components Datasheet Search |
|
HV732DB1 Datasheet(PDF) 4 Page - Supertex, Inc |
|
|
|||||||||||||||||||||||||||||
HV732DB1 Datasheet(HTML) 4 Page - Supertex, Inc |
|
4 / 8 page ![]() 4 HV732DB1 Board Voltage Supply Power-Up Sequence Connector and Test Pin Description Logic Control Signal Input Connector 1V CC Logic-high reference voltage supply V LL, +1.8V to 3.3V 2 EN Pulser output enable logic signal input, active high 3 GND Logic signal ground, 0V (3) 4P IN Pulser positive high voltage pulse output control logic signal input, active high. (2) 5 GND Logic signal ground, 0V (3) 6N IN Pulser negative high voltage pulse output control logic signal input, active high. (2) 7 GND Logic signal ground, 0V (3) 8 DAMP Pulser high voltage pulse output zero-damping control logic signal input, active high. (2) 9 GND Logic signal ground, 0V (3) 10 CLAMP Output stage P and N-MOSFETs gate-clamping control logic signal input, active high. (2) Power Supply Connector 1V CC Logic-high reference voltage supply, +1.8V to 3.3V.with current limit to 5.0mA 2 GND Low voltage power supply ground, 0V 3V LN -5V negative bias supply with current limit to 5.0mA 4V DD +9V to 12V positive driver voltage supply with current limit to 10mA 5V NN 0V to -100V Negative high voltage supply with current limit to 2.0mA (4) 6 GND High voltage power supply ground, 0V 7V PP +15V to +100V positive high voltage supply with current limit to 2.0mA (4) 8V SUB Chip substrate bias voltage, must be same as V PP with current limit to 2.0mA (4) 1V CC +15V to +100V the substrate and positive high voltages (1) 2V DD +9V to +12V positive drive supply voltage 3V SUB /VPP +1.8V to 3.3V positive logic supply voltage 4V LN -5V negative bias supply voltage 5V NN 0V to +/-100V negative high voltage (1) 6 Logic Active Any logic control active high signals Note: (1) Turn on or off with V SUB/VPP = +25V, VNN = -25V is recommend. Then ramp VPP or VNN up or down slowly if without CLAMP control signal is Hi. V SUB/VPP = +100V and VNN = -100V are maximum. (2) Overlap control signal logic-high periods may cause the device permanent damage (3) Due to the high speed control signal, every GND wire in the ribbon cable need connect to signal ground. (4) It is important to note that some the high voltage capacitors and diodes on board are only rated at 100V, if need test unipolar conditions like V SUB/VPP = +150V and VNN = -50V, or VSUB/VPP = +200V and VNN = 0V etc., their voltage ratings need to be upgraded. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |