| Electronic Components Datasheet Search |
|
E2GA3CS2000CCM Datasheet(PDF) 1 Page - Ashcroft, Inc. |
|
|
|||||||||||||||||||||||||||||
E2GA3CS2000CCM Datasheet(HTML) 1 Page - Ashcroft, Inc. |
|
1 / 6 page ![]() Data Sheet E2 Sanitary Pressure Transducer of 6 1 All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, AMP®, Deutsch®, Hirschmann®, Metri-Pack®, Neobee®, Superseal® and Tri-Clamp®. For more information, see Ashcroft Brands & Trademarks ©2024 Ashcroft Inc. e2_san_seal_trans_ds_RevG_10-24-24 ashcroft.com | 1.800.328.8258 | Contact Us E2 Sanitary Pressure Transducer PERFORMANCE SPECIFICATIONS Reference Temperature: 21 °C ±2 °C (70 °F ±3 °F) Static Accuracy: ±0.25% of span, ±0.50% of span, ±1.0% of span, Terminal Point Method includes: hysteresis, linearity, repeatability, offset and span Stability: ±0.25% year at reference conditions ENVIRONMENTAL SPECIFICATIONS Thermal Coefficients: Offset: ±0.009% /°C from -40 °C to 125 °C Span: ±0.009% /°C from -40 °C to 125 °C Humidity: 0-100% (non-condensing) FUNCTIONAL SPECIFICATIONS Response Time (Output) 4 ms Gauge/Compound Pressure Ranges: VAC to 1000 psig AbsolutePressure Ranges: 0 to 500 psia Proof Pressure: 1.2X - 2X (See Table 1 on page 2) Burst Pressure: 3X - 8X (See Table 1 on page 2) Additional Offset Temperature Error (21 °C Reference Temp.) Glycerin Silicone 1.5˝ Fitting 0.8 psi/100 °C 1.4 psi/100 °C 2.0˝ Fitting 0.5 psi/100 °C 0.7 psi/100 °C ELECTRICAL SPECIFICATIONS Circuit Protection: Reverse polarity protected INTRINSICALLY SAFE INSTALLATIONS Supply Voltage: Output 9-28 Vdc: 0-5 Vdc, 1-5 Vdc, 1-6 Vdc, 0.1-5 Vdc, 0.5-4.5 Vdc 14-28 Vdc: 0-10 Vdc, 1-11 Vdc, 0.1-10 Vdc 9-30 Vdc: 4-20 mA, 20-4 mA (2-wire) NON-INCENDIVE INSTALLATIONS: Supply Voltage: Output 9-28 Vdc: 0-5 Vdc, 1-5 Vdc, 1-6 Vdc, 0.1-5 Vdc, 0.5-4.5 Vdc 14-28 Vdc: 0-10 Vdc, 1-11 Vdc, 0.1-10 Vdc 9-30 Vdc: 4-20 mA, 20-4 mA (2-wire) Adjustability: ±5% of span non-interactive offset & span Supply Current: <8 mA (Vout) Curent Source/Sink for Voltage Output 1 mA (source)/ 0.1 mA (sink) MAX. Withstand/Breakdown 100 Vdc/Vac, optional 500 Vdc/Vac FEATURES Available with 1.5˝ and 2.0˝ Tri-Clamp® connection Ranges vacuum through 1000 psi Glycerin fill fluid is standard for ranges from 0 to 1000 psi, mineral oil fill fluid is standard on vacuum, compound and absolute ranges. Wide selection of electrical terminations Customizable configurations External magnetic offset & span adjustment SIL 3 capable TYPICAL USES Food, dairy and beverage production Pharmaceutical 3-A Sanitary applications Biotech and medical equipment Filtration KEY BENEFITS •Highly configurable •Easy calibration of offset and span •SIL certified Temperature Limits: (Subject to Fill Fluid) Code Fill Fluid Storage Operating and Media Temperature CG* Glycerine 0 °F to 257 °F (-18 °C to 125 °C) (STD.) * Standard on ranges from 0 to 1000 psig. CZ Food grade Silicone -40 °F to 257 °F (-40 °C to 125 °C) FJ Distilled water 40 °F TO 185 °F (4 °C TO 85 °C) MY* Mineral oil 10 °F to 257 °F (-12 °C to 125 °C) * Standard on all vacuum, compound and absolute ranges. NM Neobee® M20 5 °F to 257 °F (-5 °C to 125 °C) Note: Contact Ashcroft for alternate fill fluids |
Similar Part No. - E2GA3CS2000CCM |
|
Similar Description - E2GA3CS2000CCM |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |