2 / 2 page ![]() 31 23 Switching capacity up to 15A. Suitable for automation system and auxiliary automobile etc. Ordering Information N932 C 15 DC12V D 1 2 3 4 5 1 Part number N932 2 Contact arrangement C:1C 3 Contact rating 15:15A/14VDC 4 Coil rated voltage(V) DC: 12 5 Coil transient suppression: D: with diode NIL: standard Dash numbers Coil voltage VDC Coil resistance 10% Operate Time ms Release Time ms Coil Parameter N932 Contact Arrangement 1C SPDT(B-M) Contact Material Au AgNi Contact Rating (resistive) 15A/14VDC Rated Max 012-1800 12 15.6 80 8 1.2 1.8 10 8 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. Max. Switching Power 210W Max. Switching Voltage 15VDC Max. Switching Current:15A Contact Resistance or Voltage drop 50m Item 3.12 of IEC255-7 5 Operation Electrical 10 Item 3.30 of IEC255-7 7 life Mechanical 10 Item 3.31 of IEC255-7 Pickup voltage VDC(max) (67%of rated voltage ) Release voltage VDC(min) (10% of rated voltage) Coil power consumption W Features Contact Data Operation condition 1) Insulation Resistance 100M min (at 500VDC) Item 7 of IEC255-5 1) Dielectric Strength Between contacts 50Hz 500V Item 6 of IEC255-5 Between contact and coil 50Hz 500V Item 6 of IEC255-5 Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Dimensions Dimensions Mounting (Bottom view) Wiring diagram (Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. 2 Shock resistance 100m/s 11ms IEC68-2-27 Test Ea Vibration resistance 10~55Hz double amplitude 1.5mm IEC68-2-6 Test Fc Terminals strength 8N IEC68-2-21 Test Ua2 Solderability 235 2 5 0.5s IEC68-2-20 Test Ta method 1 Ambient Temperature -40~125 Relative Humidity 85% (at 40 ) IEC68-2-3 Test Ca Mass 31g Note: 1). When testing, coil terminals , if coil transient suppression is installed in relay . should be connected 30 30 86 (+) 85 87a 87 N932 31max. 20 5- 3.4 20 31 60 mm /inch 0.630max. 0.787 0.134 0.787 1.220 Ningbo Huaguan Relay Corporation LTD. NHG RELAYS |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |