| Electronic Components Datasheet Search |
|
ASL150 Datasheet(PDF) 2 Page - Astrodyne Corporation |
|
|
|||||||||||||||||||||||||||||
ASL150 Datasheet(HTML) 2 Page - Astrodyne Corporation |
|
2 / 4 page ![]() 150W 2” x 4” Open Frame Switching Power Supplies A S L 1 5 0 series ASTRODYNE USA: 1-800-823-8082 WWW.ASTRODYNE.COM ASTRODYNE EUROPE: 353 51 561060 ASTRODYNE PACIFIC: 886-2-26983458 INPUT SPECIFICATIONS Input Voltage Range (AC / DC) 90-264 / 170-370 Input Current <2.5A @ 100VAC Inrush Current No Damage @ 230VAC Cold Start Input Frequency 47-63Hz Power Factor (90VAC) 0.98% Harmonic Input Current Meets EN61000-3-2 Input Fuse 3A Internal Line & Neutral Under Voltage Lockout 80VAC Auto Recover Leakage Current (120V I/P) <275uA OUTPUT SPECIFICATIONS Setpoint Accuracy +/-1% Main Output V1 Overshoot during Power-on Out of regulation 50mS, max. Voltage Adjust 5% Main Output V1 Load Regulation +/-1% V1; +/-20% V2 Line Regulation +/-0.1% 90-264VAC Cross Regulation +/-1% V1; +/-15% V2 Transient Response (50% Load Change) 10% Recover within 1mS Start Up (HL; FL) 500mS Rise / Hold Up Time 20mS / 16mS Temperature Coefficient +/-0.25mV/°C Ripple/Noise: 20Mhz BW, resistive load, with 22uF (tantalum) and 0.47uF (ceramic) parallel capacitors at POL 1% of Output (42% 12V aux.) Over-voltage Protection 130% max. Over Current Protection 130% max. Auto Recover* Short Circuit and Over Temp Protection Auto Recovery * GENERAL SPECIFICATIONS I/P-O/P Isolation 3000VAC for 1 Minute I/P-Ground Isolation 1500VAC for 1 Minute O/P-O/P Isolation 100VDC for 1 Minute O/P-Ground Isolation 500VAC for 1 Minute ENVIRONMENTAL SPECIFICATIONS Oper. Temperature -20 to +50°C FL Derate Linearly to 50% Load at 70°C * Cooling 200LFM >100W O/P Power Relative Humidity 8-90% Non Cond (95% Non-Oper.) Storage Temperature -40 to +80°C * Operating Altitude 5000 ft Above Sea Level Derate to 40°C ambient @ 10,000 ft MTBF Convection Cooled: 150,000Hrs Air Flow (200 CFM): 300,000 Hrs EMC / CE Mark Requirements EN55024 Voltage Fluctuation EN61000-3-3 ESD 15KV Air, 8KV Contact Radiated Field 3V/m, 80-1000MHz 80% Modulation at distance of 3M EFT ±2kV on AC power port for 1 minute; ±1kV on signal/ctrl lines Surge ±1kV line to line/±2kV line to earth on AC power port; ±0.5kV for outdoor cables Conducted RF 3V; 0.15-80MHz 80% Modulation Voltage Variations >95% dip, 0.5 period; 30% dip, 25 periods; >95% reduction, 250 periods Safety Standards (PENDING) EN60950, IEC60950, UL/cUL 60950 * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |