5 / 16 page ![]() K8DT-AS 5 Timing Charts Overcurrent Operation Diagram (Output Drive Method: Normally Open) DIP switch setting: SW3 OFF, SW4 OFF Undercurrent Operation Diagram (Output Drive Method: Normally Closed) DIP switch setting: SW3 ON, SW4 ON Nomenclature Front Note: Use solid wires, stranded wires, or ferrules to connect to the terminals. To maintain the withstand voltage after connecting the terminals, insert 8 mm of exposed conductor into the terminal. Indicators Setting Knobs Hysteresis (5% to 50% of operating value) Lit Flashing t t: Operating time (0.1 to 30 s) Delay time: 250 ms (reference value) LOCK: Startup lock time (0 to 30 s) LOCK Power supply voltage Contacts 11-14 or transistor output Contacts 11-12 Set value Input Alarm indicator Hysteresis (5% to 50% of operating value) Flashing t t: Operating time (0.1 to 30 s) Power supply voltage Contacts 11-12 Set value Alarm indicator Lit Contacts 11-14 or transistor output Input Delay time: 250 ms (reference value) Terminal block (See note.) Terminal block (See note.) Current knob (SV) Hysteresis knob (HYS) Operating time knob (T) Startup lock time knob (LOCK) Power indicator Output status indicator Alarm indicator 8 mm 8 mm Solid Wire 8 mm Stranded Wires Ferrules Item Meaning Power indicator (PWR: Green) Lit when power is being supplied. Output status indicator (Output: Yellow) Lights for output Alarm indicator (ALM: Red) Lit when there is an overcurrent or undercurrent. The indicator flashes to indicate the error status after the input has exceeded the set value while the operating time is being clocked. Item Usage Current knob (SV) Used to set the current to 10% to 100% of maximum setting range. Hysteresis knob (HYS) Used to set the rest value to 5% to 50% of the operating value. Operating time knob (T) Used to set the operating time to 0.1 to 30 s. Startup lock time knob (LOCK) Used to set the startup lock time to 0 to 30 s. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |