| Electronic Components Datasheet Search |
|
SHT41A-AWSB-R3 Datasheet(PDF) 12 Page - Sensirion AG Switzerland |
|
|
|||||||||||||||||||||||||||||
SHT41A-AWSB-R3 Datasheet(HTML) 12 Page - Sensirion AG Switzerland |
|
12 / 22 page ![]() www.sensirion.com / D1 Version 1.0 – May 2025 12 / 22 5.4 I2C Command Overview Command (hex) Response length incl. CRC (bytes) Description [return values] 0xFD 6 measure T & RH with high precision (high repeatability) [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0xF6 6 measure T & RH with medium precision (medium repeatability) [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0xE0 6 measure T & RH with lowest precision (low repeatability) [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x89 6 read serial number [2 * 8-bit data; 8-bit CRC; 2 * 8-bit data; 8-bit CRC] 0x94 - soft reset [ACK] 0x39 6 activate heater with 200mW for 1s, including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x32 6 activate heater with 200mW for 0.1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x2F 6 activate heater with 110mW for 1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x24 6 activate heater with 110mW for 0.1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x1E 6 activate heater with 20mW for 1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x15 6 activate heater with 20mW for 0.1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] Table 9. Overview of I2C commands. If the sensor is not ready to process a command, e.g. because it is still measuring, it will return NACK to the I2C read header. Given heater power values are typical and valid for VDD = 5 V. At VDD = 3.3 V, heating power is reduced to 5% of the nominal value. 5.5 Conversion of Signal Output The digital sensor signals correspond to following humidity and temperature values: ������������ = (−6 + 125 ∙ ������������������ 216 − 1 ) %������������ 1 ������ = (−45 + 175 ∙ ������������ 216 − 1 ) °C 2 ������ = (−49 + 315 ∙ ������������ 216 − 1 ) °F 3 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |