| Electronic Components Datasheet Search |
|
MAX3243MPWREP Datasheet(PDF) 2 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
MAX3243MPWREP Datasheet(HTML) 2 Page - Texas Instruments |
|
2 / 17 page ![]() www.ti.com FUNCTION TABLES Each Driver (1) Each Receiver (1) MAX3243-EP 3-V TO 5.5-V MULTICHANNEL RS-232 LINE DRIVER/RECEIVER WITH ±15-kV ESD (HBM) PROTECTION SGLS328A – MARCH 2006 – REVISED MAY 2006 Flexible control options for power management are available when the serial port is inactive. The auto-powerdown feature functions when FORCEON is low and FORCEOFF is high. During this mode of operation, if the device does not sense a valid RS-232 signal, the driver outputs are disabled. If FORCEOFF is set low, both drivers and receivers (except ROUT2B) are shut off and the supply current is reduced to 1 µA. Disconnecting the serial port or turning off the peripheral drivers causes the auto-powerdown condition to occur. Auto-powerdown can be disabled when FORCEON and FORCEOFF are high and should be done when driving a serial mouse. With auto-powerdown enabled, the device is activated automatically when a valid signal is applied to any receiver input. The INVALID output is used to notify the user if an RS-232 signal is present at any receiver input. INVALID is high (valid data) if any receiver input voltage is greater than 2.7 V or less than –2.7 V or has been between –0.3 V and 0.3 V for less than 30 µs. INVALID is low (invalid data) if all receiver input voltages are between –0.3 V and 0.3 V for more than 30 µs. See Figure 5 for receiver input levels. ORDERING INFORMATION TA PACKAGE(1) ORDERABLE PART NUMBER TOP-SIDE MARKING SSOP – DB Reel of 2000 MAX3243MDBREP MB3243M –55 °C to 125°C TSSOP – PW Reel of 2000 MAX3243MPWREP MB3243M (1) Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package. INPUTS OUTPUT DRIVER STATUS VALID RIN DOUT DIN FORCEON FORCEOFF RS-232 LEVEL X X L X Z Powered off L H H X H Normal operation with auto-powerdown disabled H H H X L L L H YES H Normal operation with auto-powerdown enabled H L H YES L L L H NO Z Power off by auto-powerdown feature H L H NO Z (1) H = high level, L = low level, X = irrelevant, Z = high impedance INPUTS OUTPUTS RECEIVER STATUS RIN1, VALID RIN RIN2 FORCEOFF ROUT2B ROUT RIN3–RIN5 RS-232 LEVEL L X L X L Z Powered off while ROUT2B is active H X L X H Z L L H YES L H L H H YES L L Normal operation with auto-powerdown H L H YES H H disabled/enabled H H H YES H L Open Open H YES L H (1) H = high level, L = low level, X = irrelevant, Z = high impedance (off), Open = input disconnected or connected driver off 2 Submit Documentation Feedback |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |