| Electronic Components Datasheet Search |
|
PCF85063TP Datasheet(PDF) 12 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCF85063TP Datasheet(HTML) 12 Page - NXP Semiconductors |
|
12 / 52 page ![]() PCF85063TP All information provided in this document is subject to legal disclaimers. © NXP Semiconductors N.V. 2015. All rights reserved. Product data sheet Rev. 4 — 6 May 2015 12 of 52 NXP Semiconductors PCF85063TP Tiny Real-Time Clock/calendar The duration of the timer is affected by the register Offset (see Section 8.2.3). Only when OFFSET[6:0] has the value 00h the periods are consistent. 8.2.2.2 TF: timer flag The timer flag (bit TF) is set logic 1 on the first trigger of MI or HMI and remains set until it is cleared by command. 8.2.2.3 COF[2:0]: Clock output frequency A programmable square wave is available at pin CLKOUT. Operation is controlled by the COF[2:0] bits in the register Control_2. Frequencies of 32.768 kHz (default) down to 1 Hz can be generated for use as a system clock, microcontroller clock, input to a charge pump, or for calibration of the oscillator. Pin CLKOUT is a push-pull output and enabled at power-on. CLKOUT can be disabled by setting COF[2:0] to 111. When disabled, the CLKOUT is LOW. The duty cycle of the selected clock is not controlled but due to the nature of the clock generation, all clock frequencies except 32.768 kHz have a duty cycle of 50 : 50. The STOP bit function can also affect the CLKOUT signal, depending on the selected frequency. When the STOP bit is set logic 1, the CLKOUT pin generates a continuous LOW for those frequencies that can be stopped. For more details of the STOP bit function, see Section 8.2.1.2. [1] Duty cycle definition: % HIGH-level time : % LOW-level time. [2] Default value. [3] 1 Hz clock pulses are affected by offset correction pulses. Table 10. Effect of bits MI and HMI on INT generation Minute interrupt (bit MI) Half minute interrupt (bit HMI) Result 0 0 no interrupt generated 1 0 an interrupt every minute 0 1 an interrupt every 30 s 1 1 an interrupt every 30 s Table 11. CLKOUT frequency selection COF[2:0] CLKOUT frequency (Hz) Typical duty cycle[1] Effect of STOP bit 000[2] 32768 60 : 40 to 40 : 60 no effect 001 16384 50 : 50 no effect 010 8192 50 : 50 no effect 011 4096 50 : 50 CLKOUT = LOW 100 2048 50 : 50 CLKOUT = LOW 101 1024 50 : 50 CLKOUT = LOW 110 1[3] 50 : 50 CLKOUT = LOW 111 CLKOUT = LOW - - |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |