60 / 68 page ![]() Table 74: System Monitor Specifications (cont'd) Parameter Symbol Comments/Conditions Min Typ Max Units On-Chip Sensor Accuracy Temperature sensor error1, 3 Tj = –55°C to 125°C (with external REF) – – ±3 °C Tj = –55°C to 110°C (with internal REF) – – ±3.5 °C Tj = 110°C to 125°C (with internal REF) – – ±5 °C Supply sensor error4 Supply voltages 0.72V to 1.2V, Tj = –40°C to 100°C (with external REF) – – ±0.5 % Supply voltages 0.72V to 1.2V, Tj = –55°C to 125°C (with external REF) – – ±1.0 % All other supply voltages, Tj = –40°C to 100°C (with external REF) – – ±1.0 % All other supply voltages, Tj = –55°C to 125°C (with external REF) – – ±2.0 % Supply voltages 0.72V to 1.2V, Tj = –40°C to 100°C (with internal REF) – – ±1.0 % Supply voltages 0.72V to 1.2V, Tj = –55°C to 125°C (with internal REF) – – ±2.0 % All other supply voltages, Tj = –40°C to 100°C (with internal REF) – – ±1.5 % All other supply voltages, Tj = –55°C to 125°C (with internal REF) – – ±2.5 % Conversion Rate5 Conversion time—continuous tCONV Number of ADCCLK cycles 26 – 32 Cycles Conversion time—event tCONV Number of ADCCLK cycles – – 21 Cycles DRP clock frequency DCLK DRP clock frequency 8 – 250 MHz ADC clock frequency ADCCLK Derived from DCLK 1 – 5.2 MHz DCLK duty cycle 40 – 60 % SYSMON Reference6 External reference VREFP Externally supplied reference voltage 1.20 1.25 1.30 V On-chip reference Ground VREFP pin to AGND, Tj = –40°C to 100°C 1.2375 1.25 1.2625 V Ground VREFP pin to AGND, Tj = –55°C to 125°C 1.225 1.25 1.275 V Notes: 1. ADC offset errors are removed by enabling the ADC automatic offset calibration feature. The values are specified for when this feature is enabled. 2. See the Analog Input section in the UltraScale Architecture System Monitor User Guide (UG580). 3. When reading temperature values directly from the PMBus interface, the SYSMON has a +4°C offset due to the transfer function used by the PMBus application. For example, the external REF temperature sensor error’s range of ±3°C becomes +1°C to +7°C when the temperature is read through the PMBus interface. 4. Supply sensor offset and gain errors are removed by enabling the automatic offset and gain calibration feature. The values are specified for when this feature is enabled. 5. See the Adjusting the Acquisition Settling Time section in the UltraScale Architecture System Monitor User Guide (UG580). 6. Any variation in the reference voltage from the nominal VREFP = 1.25V and VREFN = 0V will result in a deviation from the ideal transfer function. This also impacts the accuracy of the internal sensor measurements (i.e., temperature and power supply). However, for external ratiometric type applications allowing reference to vary by ±4% is permitted. Virtex UltraScale+ FPGA Data Sheet: DC and AC Switching Characteristics DS923 (v1.10) April 26, 2019 www.xilinx.com Product Specification 60 Send Feedback |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |