Back Button TLV2556IPWR Datasheet HTML 9Page - Texas Instruments TLV2556IPWR Datasheet HTML 10Page - Texas Instruments TLV2556IPWR Datasheet HTML 11Page - Texas Instruments TLV2556IPWR Datasheet HTML 12Page - Texas Instruments TLV2556IPWR Datasheet HTML 13Page - Texas Instruments TLV2556IPWR Datasheet HTML 14Page - Texas Instruments TLV2556IPWR Datasheet HTML 15Page - Texas Instruments TLV2556IPWR Datasheet HTML 16Page - Texas Instruments TLV2556IPWR Datasheet HTML 17Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 40 page
background image
Initialize
Initialize
DATA IN Can be Tied or Held High
1
2
3
5
4
6
10
11
12
16
MSB–1 MSB–2 MSB–3 MSB–4 MSB–5
MSB–8 MSB–9 LSB+1
8
7
9
MSB–6 MSB–7
Previous Conversion Data
MSB
EOC
LSB
DATA OUT
I/O CLOCK
DATA IN
CS
D7
MSB
1
Hi-Z State
A/D Conversion Interval
t
conv
Access Cycle
Sample Cycle
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous Conversion Result
Channel Address
Output Data
Format
Pad
Zeros
1
2
3
5
4
6
10
11
12
16
MSB–1 MSB–2 MSB–3 MSB–4 MSB–5
MSB–8 MSB–9 LSB+1
D6
D5
D4
D3
D2
D1
D0
D7
8
7
9
MSB–6 MSB–7
Previous Conversion Data
MSB
EOC
Initialize
INT
LSB
DATA OUT
I/O CLOCK
DATA IN
CS
D7
MSB
1
Hi-Z State
A/D Conversion Interval
Initialize
t
conv
Access Cycle
Sample Cycle
Shift in New Multiplexer Address,
Simultaneously Shift Out Previous Conversion Result
Channel Address
Output Data
Format
Pad
Zeros
TLV2556
www.ti.com
SLAS355B – DECEMBER 2001 – REVISED DECEMBER 2015
NOTE: To minimize errors caused by noise at CS, the internal circuitry waits for a set-up time after the CS falling edge before
responding to control input signals. Therefore, no attempt should be made to clock in an address until the minimum
CS setup time has elapsed.
Figure 7. Timing for 16-Clock Transfer Using CS With DATA OUT Set for MSB First
NOTE: To minimize errors caused by noise at CS, the internal circuitry waits for a set-up time after the CS falling edge before
responding to control input signals. Therefore, no attempt should be made to clock in an address until the minimum
CS setup time has elapsed.
Figure 8. Timing for Default Mode Using CS: (16-Clock Transfer, MSB First, Ext. Ref, Pin 19 = EOC,
Input = AIN0)
Copyright © 2001–2015, Texas Instruments Incorporated
Submit Documentation Feedback
13
Product Folder Links: TLV2556



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com