Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

S25FL512SDPBFAQ13 Datasheet(PDF) 96 Page - Infineon Technologies AG

Part # S25FL512SDPBFAQ13
Description  512 Mb (64 MB) FL-S Flash
PDF  167 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  INFINEON [Infineon Technologies AG]
Direct Link  http://www.infineon.com
Logo INFINEON - Infineon Technologies AG

S25FL512SDPBFAQ13 Datasheet(HTML) 96 Page - Infineon Technologies AG

Back Button S25FL512SDPBFAQ13 Datasheet HTML 92Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 93Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 94Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 95Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 96Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 97Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 98Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 99Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 100Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 96 / 167 page
background image
Datasheet
96
001-98284 Rev. *T
2023-08-30
512 Mb (64 MB) FL-S Flash
SPI Multi-I/O, 3.0 V
Commands
All of these commands begin with an instruction code that is transferred one bit per SCK rising edge. The
instruction is followed by either a 3- or 4-byte address transferred at SDR or DDR. Commands transferring address
or data 2 or 4 bits per clock edge are called Multiple I/O (MIO) commands. For FL-S devices at 256 Mb or higher
density, the traditional SPI 3-byte addresses are unable to directly address all locations in the memory array.
These device have a bank address register that is used with 3-byte address commands to supply the high order
address bits beyond the address from the host system. The default bank address is zero. Commands are provided
to load and read the bank address register. These devices may also be configured to take a 4-byte address from
the host system with the traditional 3-byte address commands. The 4-byte address mode for traditional
commands is activated by setting the External Address (EXTADD) bit in the bank address register to ‘1’.
The Quad I/O commands provide a performance improvement option controlled by mode bits that are sent
following the address bits. The mode bits indicate whether the command following the end of the current read
will be another read of the same type, without an instruction at the beginning of the read. These mode bits give
the option to eliminate the instruction cycles when doing a series of Quad I/O read accesses.
A device ordering option provides an enhanced high performance option by adding a similar mode bit scheme
to the DDR Fast Read, Dual I/O, and Dual I/O DDR commands, in addition to the Quad I/O command.
Some commands require delay cycles following the address or mode bits to allow time to access the memory
array. The delay cycles are traditionally called dummy cycles. The dummy cycles are ignored by the memory thus
any data provided by the host during these cycles is “don’t care” and the host may also leave the SI signal at high
impedance during the dummy cycles. When MIO commands are used the host must stop driving the I/O signals
(outputs are high impedance) before the end of last dummy cycle. When DDR commands are used the host must
not drive the I/O signals during any dummy cycle. The number of dummy cycles varies with the SCK frequency or
performance option selected via the Configuration Register 1 (CR1) Latency Code (LC). Dummy cycles are
measured from SCK falling edge to next SCK falling edge. SPI outputs are traditionally driven to a new value on
the falling edge of each SCK. Zero dummy cycles means the returning data is driven by the memory on the same
falling edge of SCK that the host stops driving address or mode bits.
The DDR commands may optionally have an 8-edge Data Learning Pattern (DLP) driven by the memory, on all
data outputs, in the dummy cycles immediately before the start of data. The DLP can help the host memory
controller determine the phase shift from SCK to data edges so that the memory controller can capture data at
the center of the data eye.
When using SDR I/O commands at higher SCK frequencies (> 50 MHz), an LC that provides 1 or more dummy cycles
should be selected to allow additional time for the host to stop driving before the memory starts driving data, to
minimize I/O driver conflict. When using DDR I/O commands with the DLP enabled, an LC that provides 5 or more
dummy cycles should be selected to allow 1 cycle of additional time for the host to stop driving before the
memory starts driving the 4 cycle DLP.
Each read command ends when CS# is returned HIGH at any point during data return. CS# must not be returned
HIGH during the mode or dummy cycles before data returns as this may cause mode bits to be captured
incorrectly; making it indeterminate as to whether the device remains in enhanced high performance read mode.
9.4.1
Read (Read 03h or 4READ 13h)
The instruction
• 03h (ExtAdd = 0) is followed by a 3-byte address (A23–A0) or
• 03h (ExtAdd = 1) is followed by a 4-byte address (A31–A0) or
• 13h is followed by a 4-byte address (A31–A0)
Then the memory contents, at the address given, are shifted out on SO. The maximum operating clock frequency
for the READ command is 50 MHz.
The address can start at any byte location of the memory array. The address is automatically incremented to the
next higher address in sequential order after each byte of data is shifted out. The entire memory can therefore
be read out with one single read instruction and address 000000h provided. When the highest address is reached,



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com