Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

RM48L950DPGET Datasheet(PDF) 39 Page - Texas Instruments

Part # RM48L950DPGET
Description  RM48Lx50 16- and 32-Bit RISC Flash Microcontroller
PDF  182 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI2 [Texas Instruments]
Direct Link  https://www.ti.com
Logo TI2 - Texas Instruments

RM48L950DPGET Datasheet(HTML) 39 Page - Texas Instruments

Back Button RM48L950DPGET Datasheet HTML 35Page - Texas Instruments RM48L950DPGET Datasheet HTML 36Page - Texas Instruments RM48L950DPGET Datasheet HTML 37Page - Texas Instruments RM48L950DPGET Datasheet HTML 38Page - Texas Instruments RM48L950DPGET Datasheet HTML 39Page - Texas Instruments RM48L950DPGET Datasheet HTML 40Page - Texas Instruments RM48L950DPGET Datasheet HTML 41Page - Texas Instruments RM48L950DPGET Datasheet HTML 42Page - Texas Instruments RM48L950DPGET Datasheet HTML 43Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 39 / 182 page
background image
RM48L950, RM48L750, RM48L550
www.ti.com
SPNS174C – APRIL 2012 – REVISED JUNE 2015
4.3.2.18 Test and Debug Modules Interface
Table 4-42. ZWT Test and Debug Modules Interface
TERMINAL
RESET
SIGNAL
PULL
PULL TYPE
DESCRIPTION
337
TYPE
SIGNAL NAME
STATE
ZWT
Test enable. This terminal
must be connected to ground
TEST
U2
I/O
Fixed 100-µA
directly or through a pulldown
Pulldown
Pulldown
resistor.
nTRST
D18
Input
JTAG test hardware reset
RTCK
A16
Output
N/A
None
JTAG return test clock
Fixed 100-µA
TCK
B18
Input
Pulldown
JTAG test clock
Pulldown
Fixed 100-µA
TDI
A17
I/O
Pullup
JTAG test data in
Pullup
100 µA
TDO
C18
Output
None
JTAG test data out
Pulldown
Fixed 100-µA
TMS
C19
I/O
Pullup
JTAG test select
Pullup
4.3.2.19 Flash Supply and Test Pads
Table 4-43. ZWT Flash Supply and Test Pads
TERMINAL
RESET
SIGNAL
PULL
PULL TYPE
DESCRIPTION
337
TYPE
SIGNAL NAME
STATE
ZWT
3.3-V
VCCP
F8
N/A
None
Flash pump supply
Power
FLTP1
J5
Flash test pads. These
terminals are reserved for TI
use only. For proper operation
–
N/A
None
these terminals must connect
FLTP2
H5
only to a test pad or not be
connected at all [no connect
(NC)].
4.3.2.20 Reserved
Table 4-44. Reserved
TERMINAL
RESET
SIGNAL
PULL
PULL TYPE
DESCRIPTION
337
TYPE
SIGNAL NAME
STATE
ZWT
Reserved
A15
–
N/A
None
Reserved. These balls are
connected to internal logic but
Reserved
B15
–
N/A
None
are not outputs nor do they
have internal pulls. They are
Reserved
B16
–
N/A
None
subject to ±1 µA leakage
Reserved
A8
–
N/A
None
current.
Reserved
B8
–
N/A
None
Reserved
B9
–
N/A
None
Copyright © 2012–2015, Texas Instruments Incorporated
Terminal Configuration and Functions
39
Submit Documentation Feedback



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com