  MLX90217 Datasheet HTML 1Page - Melexis Microelectronic Systems MLX90217 Datasheet HTML 2Page - Melexis Microelectronic Systems MLX90217 Datasheet HTML 3Page - Melexis Microelectronic Systems MLX90217 Datasheet HTML 4Page - Melexis Microelectronic Systems MLX90217 Datasheet HTML 5Page - Melexis Microelectronic Systems MLX90217 Datasheet HTML 6Page - Melexis Microelectronic Systems MLX90217 Datasheet HTML 7Page - Melexis Microelectronic Systems MLX90217 Datasheet HTML 8Page - Melexis Microelectronic Systems  
Zoom Inzoom in Zoom Outzoom out
 2 / 8 page
background image
3901090217
Page 2
Jun/04
Rev. 009
MLX90217
Hall-Effect Cam Sensor
MLX90217 Electrical Specifications
DC Operating Parameters TA = -40
oC to 150oC, V
DD = 3.5V to 24V (unless otherwise specified).
Parameter
Symbol Test Conditions
Min
Typ
Max
Units
Supply Voltage
VDD
Operating
3.5
-
24
V
Supply Current
IDD
VDD = 12V
1.5
3.0
4.5
mA
Supply Current
IDD
VDD = 3.5V to 24V
1
-
6
mA
Leakage Current
ILEAK
VOUT = 3.5V to 24V
-
-
10
µA
Output Current
IOUT
Operating
-
-
25
mA
Output Saturation Voltage
VSAT
VDD = 12V, IOUT = 25mA
-
-
600
mV
Output Short Circuit Current
IFAULT
Fault
50
100
150
mA
Output Short Circuit Shutdown
TFAULT
Fault
100
-
200
µS
Clock Frequency
fCLK
Operating
300
500
800
kHz
Output Rise Time
tr
VDD=12V R1 = 880W C1 = 20pf
-
400
nS
Output Fall Time
tf
VDD=12V R1 = 880W C1 = 20pf
-
400
nS
Bandwidth
BW
Operating
-
-
15
kHz
Thermal Resistance
RTH
Operating
-
-
200
o
C/Watt
MLX90217 Magnetic Specifications
DC Operating Parameters TA = -40
oC to 150oC, V
DD = 3.5V to 24V (Unless otherwise specified)
Parameter
Symbol Test Conditions
Min
Typ
Max
Units
Back Bias Range
BBIAS
Operating
-30
-
400
mT
Linear Region
VDD = 12V
50
-
500
mT
Hysteresis
Bhys
VDD = 3.5V to 24V
1.8
3.5
10
mT
Notes: 1mT=10Gauss



Html Pages

1 2 3 4 5 6 7 8


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com