4 / 11 page ![]() PMT2 Panel Mount Power Supply PMT2 100W series / PMT-□V100W2B□□ TECHNICAL DATASHEET All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated. www.DeltaPSU.com (April 2020, Rev. 05) 4 Reliability Data MTBF > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25°C) Expected Cap Life Time 10 years (230Vac, 50% load @ 40°C) Safety Standards / Directives Safety Entry Low Voltage SELV Electrical Safety TUV Bauart cTUVus CB scheme CCC KC EAC EN 62368-1, EN60335-1, EN 61558-1/-2-16 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 GB4943 K 60950-1 TP TC 004/2011 CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU Galvanic Isolation Input to Output 4.0KVac Input to Ground 2.0KVac Output to Ground 1.25KVac EMC Emissions (CE & RE) CISPR 32, EN 55032, EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to EN55014-1, FCC Title 47, EN 61000-6-3 : Class B Immunity EN 55035, KN35, EN 61000-6-2 Compliance to EN55014-2,EN 61000-6-1 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge: 8kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2kV Surge IEC 61000-4-5 Level 4 Criteria A1) Common Mode4): 4kV Differential Mode5): 2kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Level 4 Criteria A1) 30A/Meter Voltage Dips and Interruptions IEC 61000-4-11 0% residual; 1 cycle, Criteria B 40% residual; 10 cycle, Criteria C3) 70% residual; 25 cycle, Criteria C3) Harmonic Current Emission IEC/EN 61000-3-2 Class A 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |