2 / 18 page ![]() 4-2 PBL 3766 Absolute Maximum Ratings Parameter Symbol Min Max Unit Temperature and humidity Storage temperature range T Stg -60 +150 °C Operating temperature range T Case -10 +110 °C Operating junction temperature T J -10 +140 °C Storage humidity R H 5 95 % RH Power supply, -10 °C < T Amb < 80 °C V CC with respect to GND V CC -0.5 6.5 V V EE with respect to GND V EE -6.5 0.5 V V Bat with respect to GND V Bat -70 V EE+0,7 V Power dissipation Continuous power dissipation at T Amb ≤ 70 °CPD 1.5 W Peak power dissipation at T Amb = 70°C, t < 10 ms, trep > 10 sec. P DP 4W Relay driver Ring relay supply voltage V RRly V Bat 0V Ring relay current I RRly 50 mA Ring trip comparator Input voltage V DT V Bat 0V Input current I DT -2 2 mA Digital inputs, outputs (C1, C2, E0, DET) Input voltage V ID 0V CC V Output voltage (DET disabled) V OD 0V CC V Output current (DET enabled) I OD 5mA TIPX or RINGX terminals, V BAT = -50 V TIPX or RINGX voltage, continuous, (Note 1) V T, VR V Bat 0.5 V TIPX or RINGX pulse = t ω < 10 ms, trep > 10 s (Notes 2, 3) V T, VR V Bat - 20 5 V TIPX or RINGX pulse = t ω < 1 µs, trep > 10 s (Notes 2, 3) V T, VR V Bat - 40 10 V TIP or RING pulse = t ω < 250 ns, trep > 10 s (Notes 2, 3) V T, VR V Bat - 70 15 V TIPX or RINGX current Active I Ldc + ILodc 80 mA Stand-by I Ldc 25 mA Recommended Operating Conditions Parameter Symbol Min Max Unit Case temperature T Case 090 °C V CC with respect to ground V CC 4.75 5.25 V V EE with respect to ground V EE -5.25 -4.75 V V Bat with respect to ground (Note 4) V Bat -58 -24 V Notes 1. With a diode (D 2) connected in series with the VBat supply, as shown in figure 11, -70 V may be continuously applied to the TIPX or RINGX lead. 2. These voltage ratings require a diode (D 2) to be installed in series with the VBat supply as shown in figure 11. 3. V T and VR are referenced to ground. t ω is the pulse width of a rectangular test pulse and trep is the pulse repetition rate. 4. -24 V < V Bat < -21 V may be used in applications requiring maximum vf signal amplitudes less than 3 Vpk (8.75 dBm, 600 ohms). |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |