| Electronic Components Datasheet Search |
|
EB16 Datasheet(PDF) 2 Page - LUMEL S.A. |
|
|
|||||||||||||||||||||||||||||
EB16 Datasheet(HTML) 2 Page - LUMEL S.A. |
|
2 / 6 page ![]() 2 www.lumel.com.pl AC CURRENT AND AC VOLTAGE DIRECT MEASUREMENT RANGES Frontal frame dimensions [mm] 48 x 48*) 72 x 72 96 x 96 144 x 144 Scale lenght [mm] 41 63 97 146 Weight [kg] 0.1 0.16 0.2 0.4 Type EA16, EB16 EA17 EA19 EA12 Measuring range self-consumption 100 mA < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 150 mA < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 250 mA < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 400 mA < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 600 mA < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 1 A < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 1.5 A < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 2.5 A < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 4 A < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 6 A < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 10 A < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 15 A < 0.8 VA < 0.8 VA < 0.8 VA < 0.8 VA 25 A < 0.8 VA < 0.8 VA < 0.8 VA < 0.8 VA 40 A – < 0.8 VA < 0.8 VA < 0.8 VA 60 A – < 0.8 VA < 0.8 VA < 0.8 VA 100 A – < 0.8 VA < 0.8 VA < 0.8 VA For a transformer. Measuring ranges acc. to table 2 (for current and voltage ranges) ... x/1 A < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA ... x/5 A < 0.5 VA < 0.5 VA < 0.5 VA < 0.5 VA 6 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 10 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 15 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 25 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 40 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 60 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 100 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 150 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 250 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 400 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 500 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 600 V < 4.5 VA < 4.5 VA < 4.5 VA < 4.5 VA 800 V 1) – < 4.5 VA < 4.5 VA < 4.5 VA 1000 V 1) – < 4.5 VA < 4.5 VA < 4.5 VA For a transformer. Measuring ranges acc. to table 5 .../100 V < 4,5 VA < 4,5 VA < 4,5 VA .../110 V < 4,5 VA < 4,5 VA < 4,5 VA Table 1 *) It concerns EA16 meters, for the frontal frame dimensions of EB16 meters, see Fig.1. 1)Applies only to phase-to-phase voltage measurements in a 3-phase network |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |