31 / 39 page ![]() DIO1413/1414 Version 1.2, Sep 2024 www.dioo.com © 2024 DIOO MICROCIRCUITS CO., LTD. 27 Addr. Type Register B7 B6 B5 B4 B3 B2 B1 B0 Default 22h R/W Consecutive ALERT TIME OUT CTHRM [2:0] CALRT [2:0] Reserved 70h Note: R = Read. W = Write. Bit Name Description 7 TIMEOUT 0 (default): The SMBus Timeout function is disabled. The device will not resetting its SMBus protocol even the SMCLK line being held low indefinitely. 1: The SMBus Timeout function is enabled. The device will reset the SMBus protocol if the SMCLK line is held low for more than 30ms. 6:4 CTHRM [2:0] Determines the number of consecutive temperature measurements that must exceed the corresponding Therm Limit before the ______ THERM/ADDR pin is asserted. Every temperature channel uses the same value for their therm counters. The consecutive therm counter will be increased by 1 whenever any temperature measurement exceed the Therm Limit. Once any channel’s measured temperature drops below the Therm Limit, the corresponding therm counter is reset. Once the ______ THERM/ADDR pin has been asserted, the therm counter will not reset until the corresponding channel’s measured temperature drops below the Therm Limit minus the Therm Hysteresis. The consecutive alert bits CTHRM[2:0] are decoded as shown in the following table. The default setting is 4 consecutive out of limit measurements. 3:1 CALRT [2:0] Determines the number of consecutive temperature measurements that must meet an out of limit condition or fault condition before the ——— ALERT pin is asserted. Every temperature channel uses the same for their alert counters. The consecutive alert bits CALRT[2:0] are decoded as shown in the following table. The default setting is 1 consecutive out of limit measurements. 0 Reserved Do not use. Consecutive alert/Therm settings 2 1 0 Number of consecutive out of limit measurements 0 0 0 1 (default for CALRT [2:0]) 0 0 1 2 0 1 1 3 1 1 1 4 (default for CTHRM [2:0]) 0 1 0 4 1 0 0 1 0 1 1 1 0 12.12. Beta configuration registers The Beta configuration registers are used to set or indicate external BJT type or minimum PNP Beta for the corresponding external channels. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |