| Electronic Components Datasheet Search |
|
F39-LJB2 Datasheet(PDF) 4 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
F39-LJB2 Datasheet(HTML) 4 Page - Omron Electronics LLC |
|
4 / 12 page ![]() D-30 www.sti.com/info D Wiring Basic Wiring Diagram Wiring when using manual reset mode, external device monitoring F3SJ-B Safety Light Curtains KM1 KM2 S1 S2 S1 S2 KM1, KM2 K1 : External test switch (connect to 0 V if a switch is not required) : Interlock/lockout reset switch : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) K1 KM1 KM2 F39-JD @A-L F39-JD @A-D +24 VDC 0 V Power supply (Gray) Communication line (+) (Pink) Communication line (−) Wiring for auto reset mode and deactivated external device monitoring S1 S2 KM1, KM2 K1 : External test switch (connect to 0 V if a switch is not required) : Lockout reset switch : Safety relay with force-guided contact (G7SA) or magnetic contactor : Load or PLC, etc. (for monitoring) S1 S2 K1 KM1 KM2 F39-JD @A-L F39-JD @A-D +24 VDC 0 V Power supply (Gray) Communication line (+) (Pink) Communication line (−) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|