Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

ASFM0185S Datasheet(PDF) 2 Page - Panasonic Semiconductor

Part # ASFM0185S
Description  Flat type safety relays ( 1 Form A 1Form B )
PDF  8 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  PANASONIC [Panasonic Semiconductor]
Direct Link  http://www.panasonic.com/industrial/
Logo PANASONIC - Panasonic Semiconductor

ASFM0185S Datasheet(HTML) 2 Page - Panasonic Semiconductor

  ASFM0185S Datasheet HTML 1Page - Panasonic Semiconductor ASFM0185S Datasheet HTML 2Page - Panasonic Semiconductor ASFM0185S Datasheet HTML 3Page - Panasonic Semiconductor ASFM0185S Datasheet HTML 4Page - Panasonic Semiconductor ASFM0185S Datasheet HTML 5Page - Panasonic Semiconductor ASFM0185S Datasheet HTML 6Page - Panasonic Semiconductor ASFM0185S Datasheet HTML 7Page - Panasonic Semiconductor ASFM0185S Datasheet HTML 8Page - Panasonic Semiconductor  
Zoom Inzoom in Zoom Outzoom out
 2 / 8 page
background image
Safety●Relays●SF-M●RELAYS
ASCTB434E 202009
Panasonic Corporation 2020
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
RATING
●
■ Coil●data
• Operating characteristics such as "Operate voltage" and "Release voltage" are influenced by mounting conditions, ambient
temperature, etc.
Therefore, please use the relay within ±5% of rated coil voltage.
• "Initial" means the condition of products at the time of delivery.
Contact
arrangement
Rated coil
voltage
Operate
voltage*1
( at 20℃ )
Release
voltage*1
( at 20℃ )
Rated operating
current
( ±10% at 20℃ )
Coil resistance
( ±10% at 20℃ )
Rated operating
power
Max. allowable
voltage*2
( at 20℃ )
1 Form A
1 Form B
3 V DC
Max. 75% of
rated voltage
( initial )
Min. 10% of
rated voltage
( initial )
90 mA
33.3 Ω
270 mW
(When input)
100 mW
(When retained)
120 % V of
rated voltage
5 V DC
54 mA
92.6 Ω
12 V DC
23 mA
533 Ω
16 V DC
17 mA
948 Ω
18 V DC
15 mA
1,200 Ω
21 V DC
13 mA
1,633 Ω
24 V DC
11 mA
2,133 Ω
*1: Square, pulse drive
*2: It is not allowed to apply the continuous maximum voltage to the coil.
In order to obtain the specified performance, please apply the rated voltage.
●
■ Specifications
Characteristics
Item
Specifications
Contact
Coil arrangement
1 Form A 1 Form B
Contact resistance, max ( Initial )
Max. 100 mΩ ( By voltage drop 6 V DC 1 A )
Contact material
RT Ⅱ : Au flashed AgNi type
RT Ⅲ : Au flashed AgSnO2 type
Contact rating ( resistive )
NO contact ( 5-6 terminal ) ; 6 A 250 V AC, 6 A 30 V DC
NC contact ( 3-4 terminal ) ; 4 A 250 V AC, 4 A 30 V DC
Max. switching power ( resistive ) NO contact ( 5-6 terminal ); 1,500 VA, 180 W ( 85 W : when load voltage exceeds 30 V DC )
NC contact ( 3-4 terminal ) ; 1,000 VA, 120 W ( 85 W : when load voltage exceeds 30 V DC )
Max. switching voltage
250 V AC, 125 V DC
Max. switching current
NO contact ( 5-6 terminal ) : 6 A AC, 6 A DC
NC contact ( 3-4 terminal ) : 4 A AC, 4 A DC
Min. switching load
( reference value ) *1
1 mA 10 V DC
insulation resistance ( initial )
Min. 1,000 MΩ at 500 V DC
( Measured portion is the same as the case of dielectric voltage. )
Dielectric strength
( initial )
Between open contacts
1,500 Vrms for 1 min ( Detection current: 10 mA )
Between contact and coil
NO contact ( 5-6 terminal ) - coil; 4,000 Vrms for 1 min
NC contact ( 3-4 terminal ) - coil; 2,500 Vrms for 1 min
Coil hold voltage *2
60% of rated voltage ( -40℃ to 85℃ )
Time characteristics
( initial )
Operate time
Max. 15 ms ( at rated voltage, at 20℃ , without bounce )
Release time *3
Max. 10 ms (at rated voltage, at 20℃ , without bounce, without diode )
Shock resistance
Functional
200 m/s2 ( half-sine shock pulse: 11 ms, detection time: 10 µs )
Destructive
1,000 m/s2 ( half-sine shock pulse: 6 ms )
Vibration resistance
Functional
10 Hz to 55 Hz ( at double amplitude of 2.5 mm, detection time: 10µs )
Destructive
10 Hz to 55 Hz ( at double amplitude of 3.5 mm )
Expected life
Mechanical life
Min. 10×106 ( at 180 times/min )
Conditions
Conditions for usage,
transport and storage *4
Ambient temperature: -40℃ to 85℃
Humidity: 5% RH to 85 % RH ( Avoid icing and condensation )
Unit weight
Approx. 6.5 g
*1: This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2: Coil holding voltage is the coil voltage after 100 ms from the application of rated coil voltage.
*3: If a diode is connected across the coil in parallel, the release time will be delayed. Check this under actual operating conditions.
*4: For ambient temperature, please read "GUIDELINES FOR RELAY USAGE".
●
■ Expected●electrical●life
Condition: Resistive load, at 6 times/min ( ON: OFF = 1 s: 9 s )
Type
Switching capacity
Number of operations
RT Ⅱ , RT Ⅲ
NO contact
( 5-6 terminal )
6A 250 V AC ( resistive )
100×103
6A 30 V DC ( resistive )
100×103
NC contact
( 3-4 terminal )
4A 250 V AC ( resistive )
100×103
4A 30 V DC ( resistive )
100×103
ー 2 ー



Html Pages

1 2 3 4 5 6 7 8


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com