Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

NB680A Datasheet(PDF) 13 Page - Monolithic Power Systems

Part # NB680A
Description  28V, Low Iq, High-Current, Fixed 3.36V, 8A,Synchronous Buck Converter with 100mA LDO and LP# Vout Scaling
PDF  18 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MPS [Monolithic Power Systems]
Direct Link  http://www.monolithicpower.com
Logo MPS - Monolithic Power Systems

NB680A Datasheet(HTML) 13 Page - Monolithic Power Systems

Back Button NB680A Datasheet HTML 9Page - Monolithic Power Systems NB680A Datasheet HTML 10Page - Monolithic Power Systems NB680A Datasheet HTML 11Page - Monolithic Power Systems NB680A Datasheet HTML 12Page - Monolithic Power Systems NB680A Datasheet HTML 13Page - Monolithic Power Systems NB680A Datasheet HTML 14Page - Monolithic Power Systems NB680A Datasheet HTML 15Page - Monolithic Power Systems NB680A Datasheet HTML 16Page - Monolithic Power Systems NB680A Datasheet HTML 17Page - Monolithic Power Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 18 page
background image
NB680A―28V, FIXED 3.36V-8A BUCK CONVERTER WITH LDO AND VOUT SCALING
NB680A Rev. 1.03
www.MonolithicPower.com
13
7/27/2017
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2017 MPS. All Rights Reserved.
Add a ceramic capacitor with a value between
4.7
μF and 22µF close to the LDO pins to
stabilize the LDOs.
LDO Switch Over
When the output voltage becomes higher than
3.15V, and the power good (PG) is OK, the
internal LDO regulator is shut off, and the LDO
output is connected to VOUT by the internal
switch-over MOSFET. This helps reduce the
power loss from the LDO.
CLK for Charge Pump
The 250kHz CLK signal drives an external
charge pump circuit to generate approximately
10V-12V DC voltage. The CLK voltage becomes
available once Vin is higher than the UVLO
threshold, and EN is pulled high (see Figure 5).
CLK
5V
12V/100mA
100nF
100nF
100nF
100nF
100nF
PGND
PGND
PGND
Figure 5: Charge Pump Circuit
Power Good (PG)
The NB680A has power-good (PG) output used
to indicate whether the output voltage of the buck
regulator is ready. PG is the open drain of a
MOSFET. It should be connected to VCC or other
voltage source through a resistor (e.g.,100k).
After the input voltage is applied, the MOSFET is
turned on, so PG is pulled to GND before SS is
ready. Once the FB voltage rises to 95% of the
REF voltage, PG is pulled high after 750µs.
When the FB voltage drops to 85% of the REF
voltage, PG is pulled low.
Over-Current Protection (OCP)
NB680A has cycle-by-cycle over-current limiting
control.
The
current-limit
circuit
employs
a
"valley" current-sensing algorithm. The part uses
the Rds(on) of the LS-FET as a current-sensing
element. If the magnitude of the current-sense
signal is above the current-limit threshold, the
PWM is not allowed to initiate a new cycle.
The trip level is fixed internally. The inductor
current is monitored by the voltage between GND
and SW. GND is used as the positive current
sensing node, so GND should be connected to
the source terminal of the bottom MOSFET.
Since the comparison is done during the HS-FET
off and the LS-ET on state, the OC trip level sets
the valley level of the inductor current. Thus, the
load current at an over-current threshold (IOC) can
be calculated with Equation (2):
 inductor
OC
I
I
I _ limit
2
(2)
In an over-current condition, the current to the
load exceeds the current to the output capacitor;
thus
the
output
voltage
tends
to
fall
off.
Eventually, it ends up crossing the under-voltage
protection threshold and shuts down. Fault
latching can be re-set by EN going low or the
power cycling of VIN.
Over/Under-Voltage Protection (OVP/UVP)
The NB680A monitors the output voltage to
detect
over
and
under
voltage.
Once
the
feedback voltage becomes higher than 122% of
the target voltage, the OVP comparator output
goes high, and the circuit latches as the HS-FET
driver turns off, and the LS-FET driver turns on,
acting as an -2A current source.
To protect the part from damage, there is an
absolute OVP on VOUT, usually set at 6.2V.
Once the Vout > 6.2V, the controller turns off
both
the
HS-FET
and
the
LS-FET.
This
protection is not latched off; it will keep switching
once the Vout returns to its normal value.
When the feedback voltage drops below 75% of
VREF but remains higher than 50% of VREF, the
UVP-1 comparator output goes high. The part is
latched if the FB voltage remains in this range for
about 32µs (latching the HS-FET off and the LS-
FET on). The LS-FET remains on until the
inductor current reaches zero. During this period,
the valley current limit helps control the inductor
current.
When the feedback voltage drops below 50% of
VREF, the UVP-2 comparator output goes high.
The part latches off directly after the comparator
and logic delay (latching the HS-FET off and the
LS-FET on). The LS-FET remains on until the
inductor current reaches zero. Fault latching can
be re-set by EN going low or the power cycling of
VIN.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com