16 / 36 page ![]() AD2S1210 Rev. 0 | Page 16 of 36 THEORY OF OPERATION RESOLVER TO DIGITAL CONVERSION The AD2S1210 operates on a Type II tracking closed-loop principle. The output continually tracks the position of the resolver without the need for external conversion and wait states. As the resolver moves through a position equivalent to the least significant bit weighting, the output is updated by one LSB. The converter tracks the shaft angle θ by producing an output angle ϕ that is fed back and compared to the input angle θ, and the resulting error between the two is driven towards 0 when the converter is correctly tracking the input angle. To measure the error, S3 − S1 is multiplied by cosϕ and S2 − S4 is multiplied by sinϕ to give φ θ ω cos sin sin 0 × t E (for S3 − S1) φ θ ω sin cos sin 0 × t E (for S2 − S4) The difference is taken, giving ) sin cos cos (sin sin 0 φ θ φ θ ω − × t E (2) This signal is demodulated using the internally generated synthetic reference, yielding ) sin cos cos (sin 0 φ θ φ θ − E (3) Equation 3 is equivalent to E0sin(θ − ϕ), which is approximately equal to E0(θ − ϕ) for small values of θ − ϕ, where θ − ϕ = angular error. The value E0 (θ − ϕ) is the difference between the angular error of the rotor and the digital angle output of the converter. A phase-sensitive demodulator, some integrators, and a compensa- tion filter form a closed-loop system that seeks to null the error signal. When this is accomplished, ϕ equals the Resolver Angle θ within the rated accuracy of the converter. A Type II tracking loop is used so that constant velocity inputs can be tracked without inherent error. FAULT DETECTION CIRCUIT The AD2S1210 fault detection circuit can sense loss of resolver signals, out-of-range input signals, input signal mismatch, or loss of position tracking; however, in the event of a fault, the position indicated by the AD2S1210 may differ significantly from the actual shaft position of the resolver. Monitor Signal The AD2S1210 generates a monitor signal by comparing the angle in the position register to the incoming sine and cosine signals from the resolver. The monitor signal is created in a similar fashion to the error signal described in the Resolver to Digital Conversion section. The incoming signals, sinθ and cosθ, are multiplied by the sin and cos of the output angle, respectively, and then added together. φ θ φ θ cos cos 2 sin sin 1 × × + × × = A A Monitor (4) where: A1 is the amplitude of the incoming sine signal (A1 × sinθ). A2 is the amplitude of the incoming cosine signal (A2 × cosθ). θ is the resolver angle. ϕ is the angle stored in the position register. Note that Equation 4 is shown after demodulation, with the Carrier Signal sinωt removed. Also, note that for matched input signal (that is, a no fault condition), A1 = A2. When A1 = A2 and the converter is tracking (θ = ϕ), the monitor signal output has a constant magnitude of A1 (Monitor = A1 × (sin2 θ + cos2 θ) = A1), which is independent of shaft angle. When A1 ≠ A2, the monitor signal magnitude varies between A1 and A2 at twice the rate of shaft rotation. The monitor signal is used as described in the following sections to detect degradation or loss of input signals. Loss of Signal Detection The AD2S1210 indicates that a loss of signal (LOS) has occurred for four separate conditions. • When either resolver input (sine or cosine) falls below the specified LOS sine/cosine threshold. This threshold is defined by the user and is set by writing to the internal register, Address 0x88 (see the Register Map section). • When any of the resolver input pins (SIN, SINLO, COS, or COSLO) are disconnected from the sensor. • When any of the resolver input pins (SIN, SINLO, COS, or COSLO) are clipping the power rail or ground rail of the AD2S1210. Refer to the Sine/Cosine Input Clipping section. • When a configuration parity error has occurred. Refer to the Configuration Parity Error section. A loss of signal is caused if either of the stator windings of the resolver (sine or cosine) are open circuit or have a number of shorted turns. LOS is indicated by both the DOS and LOT pins latching as logic low outputs. The DOS and LOT pins are reset to a no fault state when the user enters configuration mode and reads the fault register. The LOS condition has priority over both the DOS and LOT conditions, as shown in Table 6. To determine the cause of the LOS fault detection, the user must read the fault register, Address 0xFF (see the Register Map section). When a loss of signal is detected due to the resolver inputs (sine or cosine) falling below the specified LOS sine/cosine threshold, the electrical angle through which the resolver may rotate before the LOS can be detected by the AD2S1210 is referred to as the LOS angular latency. This is defined by the specified LOS sine/ cosine threshold set by the user and the maximum amplitude of the input signals being applied to the AD2S1210. The worst-case angular latency can be calculated as follows: |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |