13 / 29 page ![]() HA17384SPS/SRP, HA17384HPS/HRP, HA17385HPS/HRP Rev.3.00 Jun 15, 2005 page 13 of 28 VCOMP COMP terminal (Error output) PWM pulse Latch setting pulse (Implemented in triagular wave oscillator) Latch setting pulse VCOMP Error voltage VCS Current sensing level R S Q 1 V VCS CS terminal 2 R R 2VF × 1 3 − + CS CS latch Figure 3 Operation Diagram of Current Sensing Part Point: Error Amplifier Output Voltage Vcomp (V) Light load Heavy load 1) At maximum rated load, the setting should be made to give approximately 90% of area A below. 2) When the OVP latch is operated, the setting should be made in area B or C. 1.0 0.8 0.6 0.4 0.2 0.0 012345678 B A C 1.4V 4.4V 7.5V A : Stationary operation / PWM (Current-mode operation) B : Current limit operation / Max duty cycle C : No sensitivity area / No PWM output Figure 4 Current Sense Characteristics |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|