HV9906DB2
Instructions
2
07/23/02
B1
F1
1/2A
1
D1
L3
100uH
LED1
LED
M1
IRFR320
L2
100uH
R1
22
HV9906
GND
NEG
Q1
MMBT2907
6
D5
MURS160
D
F0
4S
RTN
R3
.47
8
7
E1
C2
.1
C5
0.1
R6
121K
R4
976K
5
D4
C6
10uF
R5
12.1K
4
D3
E2
D2
2
DUT
D7
MURS120
3
R7
100K
C3
0.033
D6
MURS120
Supertex, Inc. 1235 Bordeaux Drive, Sunnyvale, CA 94089 TEL: (408) 744-0100 FAX: (408) 222-4895 www.supertex.com
NEG, RTN
Connect your LED to these terminals: negative to
NEG, positive to RTN.
E1, E2
Connect 80 to 135VAC, 60Hz line source to these
terminals: line to E1, neutral to E2. The input is
protected with a 0.5A fuse. IMPORTANT: Make sure
that your LED is connected to NEG and RTN
terminals. There is no open circuit protection
available in this demo board. Contact Supertex, Inc.
for the application circuit if protection is required.
GND
This is circuit common.
Note that since galvanic isolation is not provided,
connecting this point to an earth-grounded instrument
(such as an oscilloscope) will short the AC line,
resulting in circuit and/or instrument damage.
Also note that GND may be at higher potential with
respect to earth ground, even if the AC is switched
off. Use caution!
Do not connect to earth-ground.
Setting Output Current
Output current is preset to 400mA for this board.
Output current can be re-programmed according to
the following equation:
V
R
R
R
R
Iout
1
3
7
7
6
⋅
⋅
−
=
The average output current will come out 5-10%
smaller due to power transfer interruptions during the
AC line voltage cusps.
Schematic Diagram



Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com