| Electronic Components Datasheet Search |
|
BXA10 Datasheet(PDF) 2 Page - Emerson Network Power |
|
|
|||||||||||||||||||||||||||||
BXA10 Datasheet(HTML) 2 Page - Emerson Network Power |
|
2 / 4 page ![]() Rev.03.07.07 bxa10 2 of 4 Embedded Power for Business-Critical Continuity All specifications are typical at nominal input, full load at 25 °C unless otherwise stated. Specifications EMC CHARACTERISTICS Conducted emissions EN55022, FCC (See Note 8) Level A ESD air EN61000-4-2, level 2 Perf. criteria 1 ESD contact EN61000-4-2, level 3 Perf. criteria 1 Surge EN61000-4-5, level 2 Perf. criteria 1 Fast transients EN61000-4-4, level 2 Perf. criteria 1 Radiated immunity EN61000-4-3, level 3 Perf. criteria 1 Conducted immunity EN61000-4-6, level 3 Perf. criteria 1 GENERAL SPECIFICATIONS Efficiency See table Isolation voltage Input/output 1500 Vdc Input or output to case 1000 Vdc Switching frequency Fixed 400 kHz Approvals and Safety VDE0805, EN60950, IEC950 standards UL1950, CSA C22.2 No. 950 Case material Black coated, six-sided metal case Material flammability UL94V-0 Weight 20 g (0.71 oz) MTBF MIL-HDBK-217F 519,000 hours Bellcore >2 million hours ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient -25 °C to +71 °C (See derating curve) Non-operating amb. -55 °C to +125 °C Case +110 °C max. Derating See derating curve Cooling Free air convection cooled Relative humidity Non-condensing 5% to 95% RH Altitude Operating 10,000 feet max. Non operating 40,000 feet max. Vibration 5-500 MHz 2.5 G rms (approx.) OUTPUT SPECIFICATIONS Line regulation LL to HL, single output ±0.2% LL to HL, dual output ±0.2% Load regulation 10% to 100% FL (See Note 4) ±0.5% Minimum load 48 V models 10% full load 12 V models No minimum load Overshoot At start-up 10% max. Ripple and noise 5 Hz to 20 MHz 100 mV pk-pk, max. (See Note 2) 20 mV rms Transient response 25% load step ±2.0% max. dev., 250 μs recovery to within ±1.0% Temperature coefficient ±0.02%/°C max. Overvoltage protection Clamp type See table Short circuit protection Hiccup Continuous automatic recovery INPUT SPECIFICATIONS Input voltage range 12 Vdc (See Note 6) 9-18 Vdc 48 Vdc 18-75 Vdc Input filter Pi type Start up surge current Resistive load 1.5 A max. Remote ON/OFF Open collector compatible ON (See Note 3) High impedance >400 kΩ OFF Low impedance <1.0 kΩ OFF idle current <1.5 mA Start-up time 1.6 s, max. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |