| Electronic Components Datasheet Search |
|
ADT7482ARMZ Datasheet(PDF) 4 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADT7482ARMZ Datasheet(HTML) 4 Page - ON Semiconductor |
|
4 / 20 page ![]() ADT7482 http://onsemi.com 4 ELECTRICAL CHARACTERISTICS (TA = −40°C to +120°C, VDD = 3.0 V to 3.6 V, unless otherwise noted. Parameter Test Conditions Min Typ Max Unit Power Supply Supply Voltage, VDD 3.0 3.30 3.6 V Average Operating Supply Current, IDD 0.0625 conversions/sec rate (Note 1) 240 350 mA Standby mode 5.0 30 mA Undervoltage Lockout Threshold VDD input, disables ADC, rising edge 2.55 V Power−On Reset Threshold 1.0 2.5 V Temperature−to−Digital Converter Local Sensor Accuracy 0°C ≤ TA ≤ +70°C 0°C ≤ TA ≤ +85°C −40°C ≤ TA ≤ +100°C ±1.0 ±1.5 ±2.5 °C Resolution 1.0 °C Remote Diode Sensor Accuracy (Note 2) 0°C ≤ TA ≤ +70°C, −55°C ≤ TD ≤ +150°C 0°C ≤ TA ≤ +85°C, −55°C ≤ TD ≤ +150°C −40°C ≤ TA ≤ +100°C, −55°C ≤ TD ≤ +150°C ±1.0 ±1.5 ±2.5 °C Resolution 0.25 °C Remote Sensor Source Current High level (Note 3) Mid level (Note 3) Low level (Note 2) 220 82 13.5 mA Maximum Series Resistance Cancelled Resistance split evenly on D+ and D− lines 1.5 kW Conversion Time From stop bit to conversion complete (all channels) one−shot mode with averaging switched on 71 11.5 93 ms One−shot mode with averaging off (conversion rate = 16, 32, or 64 conversions per second) 71 11.5 15 ms Open−Drain Digital Outputs (THERM, ALERT / THERM2) Output Low Voltage, VOL IOUT = −6.0 mA 0.4 V High Level Output Leakage Current, IOH VOUT = VDD 0.1 1.0 mA SMBus Interface (Note 3 and 4) Logic Input High Voltage, VIH SCLK, SDATA 2.1 V Logic Input Low Voltage, VIL SCLK, SDATA 0.8 V Hysteresis 500 mV SDA Output Low Voltage, VOL IOUT = −6.0 mA 0.4 V Logic Input Current, IIH, IIL −1.0 +1.0 mA SMBus Input Capacitance, SCLK, SDATA 5.0 pF SMBus Clock Frequency 400 kHz SMBus Timeout (Note 5) User programmable 25 64 ms SCLK Falling Edge to SDATA Valid Time Master clocking in data 1.0 ms 1. See Table 11for conversion rates. 2. Guaranteed by characterization, but not production tested. 3. Guaranteed by design, but not production tested. 4. See the Timing Specifications section for more information. 5. Disabled by default. For details on enabling the SMBus, see the Serial Bus Interface section. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |